Read Sony KV-30XBR910 Service Manual online
— 22 —
KV-30XBR910/34XBR910
SECTION 3: SAFETY RELATED ADJUSTMENTS
3-1. PREPARATION BEFORE CONFIRMATION
Standard ............................................................................. 135.3 ± 1 VAC
Check Condition:
AC input voltage: 120 (± 2) VAC
Note: If using a stabilized power supply, make sure that the distortion
factor is 3% or less.
Setting Mode: ............................................................................ Full mode
Signal Input: ............................................................Cross-hatch of NTSC
Initial Setting: .....................................................Standard Reset condition
Confi rm Point:............................ Across CN5509 PIN 9 for B+ of D Board
3-1.1 HOLD-DOWN
OPERATION
CONFIRMATION
1. Using an external DC power supply, apply 5.3 ± 0.5 Vdc between
Pin 2 of CN507 (jig connector) and ground (Pin 8); confi rm set goes
to hold-down (main power relay click).
to hold-down (main power relay click).
2. Remove the external DC power supply.
3-2. B+ MAX CONFIRMATION
Standard
135.3 ± 1 VAC
Check Condition:
AC input voltage: 120 (± 2) VAC
Note: If using a stabilized power supply, make sure that the distortion
factor is 3% or less.
Setting Mode: ............................................................................ Full mode
Signal Input: ............................................................Cross-hatch of NTSC
Initial Setting: .....................................................Standard Reset condition
Confi rm Point:............................ Across CN5509 PIN 9 for B+ of D Board
Click on the first or last page to see other KV-30XBR910 service manuals if exist.