KV-29FS100 (serv.man2) - Sony TV Service Manual (repair manual). Page 15

Read Sony KV-29FS100 (serv.man2) Service Manual online

— 16 —
KV-29FS100/29FV300/34FS100/
34FV250/38FV250
SECTION 3:  SAFETY RELATED ADJUSTMENTS
3-1.  R530, R531 CONFIRMATION METHOD 
(HOLD-DOWN CONFIRMATION) AND 
READJUSTMENTS
Always perform the following adjustments when replacing the following 
components marked with a Y  mark on the schematic diagram:
� ������
�� ���� ����
����� ����� ����� �����
������ ����� ����� �����
����� ����� ����� �����
����� ����
����� ����
���� �������� � �
���������� � �
3-1-1.  PREPARATION BEFORE 
CONFIRMATION
1.  Using a Variac, apply AC input voltage: 120 +/- 2.0 VAC.
2.  Turn the POWER switch ON.
3.  Input a white signal and set the PICTURE and BRIGHT controls to 
maximum.
4.  Confirm that the voltage of more than 23.0 VDC appears between 
TP85 and ground on the A Board. 
3-1-2.  HOLD-DOWN OPERATION 
CONFIRMATION
1.  Connect the current meter between Pin 11 of the FBT (T503) and the 
PWB land where Pin 11 would normally attach. (See Figure 1).
2.  Input a dot signal and set PICTURE and BRIGHTNESS to minimum: 
IABL = 2175 + 100/ -325 µA.
3.  Confirm the voltage of A Board TP91 is 135 ± 1.5 VDC.
4.  Connect the digital voltmeter and the DC power supply to TP85 and 
ground. (See Figure 1)
5.  Increase the DC power voltage gradually until the picture blanks out.
6.  Turn DC power source off immediately.
7.  Read the digital voltmeter indication (standard = 27.24 + 0.0/ - 0.1 
VDC). 
8.  Input a white signal and set PICTURE and BRIGHTNESS to 
maximum: IABL = 2175 + 100/ -325 µA.
9.  Repeat steps 4 to 7.
3-1-3.  HOLD-DOWN READJUSTMENT
If the setting indicated in Step 2 of Hold-Down Operation Confirmation 
cannot be met, readjustment should be performed by altering the 
resistance value of R530, R531 component marked with X. 
 
3mA DC range
+
-
+
-
A
+
-
FBT
TP85
T503
FBT
TP85
R531 R530
DC Power Supply
digital multimeter
ammeter
 
 
Figure 1
3-2.  B+ VOLTAGE CONFIRMATION AND 
ADJUSTMENTS
Always perform the following adjustments when replacing the following 
components, which are marked with Y on the schematic diagram on the 
GK Board:
     GK BOARD:   IC600, PH602 
1.  Using a Variac, apply AC input voltage: 130 + 2.0/-0.0 VAC
2.  Input a monoscope signal.
3.  Set the PICTURE control and the BRIGHT control to  
 
minimum.
4.  Confirm the voltage on A Board between TP23 and ground is less 
than 136.5 VDC.
5.  If step 4 is not satisfied, replace R530 and R531 on A Board and 
repeat the above steps.    
               
Page of 85
Display

Click on the first or last page to see other KV-29FS100 (serv.man2) service manuals if exist.