- 17 -
2-11. Wire Dressing 1
Ensure that wires do not touch heatsinks and high temperature
hotspots. All wires must be kept at a minimum distance of
20mm away from the EHT lead
20mm
20mm
2-9. Side Control Module Removal
2-10. H2 Board Removal
Remove the two screws fixing the user control module to the
side of the set. The control module can then be removed by
sliding it towards the rear of the set allowing access to the H2
Board.
Screws
To remove the H2 Board release the two clips circled and ease
the board gently away from the support bracket.
Clips
2-12. Wire Dressing 2
It is essential that the EHT lead is dressed in the three purse
locks as shown above to avoid contact with the carbon of the
CRT.