2-4.  SCREEN (G2)
1.  Before beginning adustment procedure:
 
-Set Picture and Brightness to “STANDARD”.
 
-Set TV to Video mode.
 
-Set WHBL 016 “RGBB” to 01
2.  Connect R, G, B of the CV board cathode to oscilloscope.
3.  Adjust Brightness to obtain the cathode value to the value shown 
below:
Cathode setting voltage:
170 V 
± 2 (VDC)
4.  Adjust SCREEN VR on the FBT until the scanning line disappears.
5.  Set WHBL 16 “RGBB” back to 00.