Convergence Rough Adjustment
Before performing this adjustment, perform Horizontal and Vertical Static 
Convergence Adjustment.
Input cross hatch pattern.
 
a)  TLH
 
Adjust the horizontal convergence of red and blue dots by inserting 
TLH Correction Plate to the DY pocket (left or right).
 
b)  YCH
 
Adjust YCH to balance Y axis.
 
c)  TLV
 
Adjust the vertical convergence of red and blue dots.
 
d)  XCV
 
Adjust XCV to balance X-axis.
TLV
R B
YCH
R
B
XCV
B
R
TLH
B
R
(VR1)
TLV1 (no need to adjust)
DY pocket
DY pocket
TLH Plate
(VR3)
TLV2
(XCV)
(VR2)
YCH
ON DY :
Screen Corner Convergence
Affix a Piece A (110), Convergence Correct/Permaloy Assy Correction to 
the misconverged areas. 
b
a
c
d
a-d : screen-corner
        misconvergence
a1
b1
c1
d1
a1~d1: Piece A(110), Convergence Correct
or
Permaloy Assy Correction
2-3.  FOCUS ADJUSTMENT
FOCUS  adjustment  should  be  completed  before  White  Balance 
adjustment. (See 3-4. WHITE BALANCE ADJUSTMENT)
1.  Receive digital monoscope pattern.
2.  Set Picture Mode to “STANDARD”.
3.  Adjust focus VR to obtain a just focus at the center of the screen.
4.  Change the receiving signal to white pattern and blue back.
5.  Confirm magenta ring is not noticeable. In case magenta ring is 
obvious, then adjust FOCUS VR to balance magenta ring and 
FOCUS.