KV-24FS100 (serv.man2) - Sony TV Service Manual (repair manual). Page 2

Read Sony KV-24FS100 (serv.man2) Service Manual online

— 13 —
KV-24FS100/25FS100
DYNAMIC CONVERGENCE  ADJUSTMENT
Before performing this adjustment, perform Horizontal  and Vertical 
Static Convergence Adjustment.
1.  Slightly loosen deflection yoke screw.
2.  Remove deflection yoke spacers.
3.  Move the deflection yoke for best convergence as  
 
shown below:
B
G
R
G
B
R
G
B
R
R
R
G
B
G
B
G
B
R
B
G
R
G
B
G
B
R
R
G
B
G
G
B
R B
R
R
4.  Tighten the deflection yoke screw.
5.  Install the deflection yoke spacers.
TLH PLATE ADJUSTMENT
1.  Input crosshatch pattern.
2.  Adjust PICTURE QUALITY to standard, PICTURE and 
BRIGHTNESS to 50%, and OTHER to standard.
3  Adjust the Horizontal Convergence of red and blue dots by tilting 
the TLH plate on the deflection yoke.
(TLV)
YCH
XCV
TLV
CV
Board
RV1750
 V.STAT
TLH Plate
  B R      R B
(R)(B)  (B)(R)
TLH+
TLH-
4.  Adjust XCV core to balance X axis.
5.  Adjust YCH VR to balance Y axis.
6.  Adjust vertical red and blue convergence with V.TILT (TLV VR.) 
  Note: Perform adjustment 3-6 while tracking items 1 and 2.
SCREEN-CORNER CONVERGENCE
1.  Affix a permalloy assembly corresponding to the misconverged 
areas: 
b
a
c
d
a
b
d
a-d: screen-corner
misconvergence
c
2-3.  FOCUS
1.  Adjust FOCUS control for best pictures.
2-4.  SCREEN (G2)
1.  Input a dot pattern.
2.  Set the PICTURE and BRIGHTNESS controls at minimum and 
COLOR control at normal.
3.  Adjust SBRT, GCUT, BCUT in service mode with an oscilloscope as 
shown below so that voltages on the red, green, and blue cathodes 
are 160 ± 2VDC.
4.  Observe the screen and adjust SCREEN (G2) VR in FBT to obtain 
the faintly visible background of dot signal. 
Focus (FV)
Screen (G2)
Pedestal
160 ± 2VDC
Ground
±
Page of 4
Display

Click on the first or last page to see other KV-24FS100 (serv.man2) service manuals if exist.