— 9 —
KP-53V100
Self-diagnosis function operation 
 
OCP 
Low B and +B line detect DET SHORT, and shut-down POWER ON RELAY. 
 
Reset by turning power on/off. 
 
In case of +B is loaded approx. 1.3A or more, microcomputer detects it via IC651. 
OVP 
In case of +B becomes approx. 150V or more, POWER ON RELAY shuts down and microcomputer detects it via IC651. 
 
Reset by turning power on/off just the same as OCP. 
V Stop  In case of microcomputer detects 2 seconds or more interval of V Pulse, Reference Pulse turns off by turning off the picture 
 
signal in YC Jungle IC (IC206). 
 
After the picture signal turns off, V Pulse is regenerated 2 seconds or more, the picture signal turns on. 
AKB 
IK detection.  Makes LED blinking in case of microcomputer doesn’t detect IK returns of IC206 CXA2147Q 30 seconds or more. 
H Stop  In case of HV becomes 33kV or more, IC502 detects it and shut-down H Drive Pulse. 
 
Microcomputer receives H Stop data from IC206 and makes LED blinking. 
Audio 
In case of DC component overlaps the output of Audio Amp., microcomputer detects it and makes LED blinking. 
 
Microcomputer forces to shut down the power. 
       