Read Sony KLV-B15G10 / KLV-B20G10 Service Manual online
– 9 –
KLV-B15G10/B20G10
RM-Y1108
2-5. PAL WHITE BALANCE ADJUSTMENT
(CUTOFF)
(1) Select AV1.
(2) Set Picture Mode to “PERSONAL” and adjust to
(2) Set Picture Mode to “PERSONAL” and adjust to
following condition:-
Color temperature ‘NORMAL’, Picture 100,
Brightness 50, Color 50, Backlight 100, Power
Saving ‘OFF’.
Color temperature ‘NORMAL’, Picture 100,
Brightness 50, Color 50, Backlight 100, Power
Saving ‘OFF’.
(3) Input PAL CVBS 20 IRE full field signal to AV1.
(4) Adjust Cut off registers:
(4) Adjust Cut off registers:
NORMAL_PAL_RCH & RCL (R Cut off)
NORMAL_PAL_BCH & BCL (B Cut off)
NORMAL_PAL_BCH & BCL (B Cut off)
(5) The cut off registers stated in item no.4 is listed in
‘Service Menu’, accessible from TT menu
(refer 2-3).
(refer 2-3).
(6) To adjust for 20”, perform step 1~3
, then press
“TT94” (in TT MODE) and continue step 4~5.
2-6. SECAM WHITE BALANCE ADJUSTMENT
(HIGHLIGHT)
(1) Select AV1.
(2) Set Picture Mode to “PERSONAL” and adjust to
(2) Set Picture Mode to “PERSONAL” and adjust to
following condition:-
Color temperature ‘NORMAL’, Picture 100,
Brightness 50, Color 50, Backlight 100, Power
Saving ‘OFF’
Color temperature ‘NORMAL’, Picture 100,
Brightness 50, Color 50, Backlight 100, Power
Saving ‘OFF’
(3) Input SECAM CVBS 70 IRE full field signal to AV1.
(4) Adjust Highlight registers:
(4) Adjust Highlight registers:
NORMAL_SECAM_RDH & RDL (R Drive)
NORMAL_SECAM_BDH & BDL (B Drive)
NORMAL_SECAM_BDH & BDL (B Drive)
(5) The highlight registers stated in item no.4 is listed in
‘Service Menu’, accessible from TT menu
(refer 2-3).
(refer 2-3).
(6) To adjust for 20”, perform step 1~3
, then press
“TT94” (in TT MODE) and continue step 4~5.
2-7. SECAM WHITE BALANCE ADJUSTMENT
(CUTOFF)
(1) Select AV1.
(2) Set Picture Mode to “PERSONAL” and adjust to
(2) Set Picture Mode to “PERSONAL” and adjust to
following condition:-
Color temperature ‘NORMAL’, Picture 100,
Brightness 50, Color 50, Backlight 100, Power
Saving ‘OFF’.
Color temperature ‘NORMAL’, Picture 100,
Brightness 50, Color 50, Backlight 100, Power
Saving ‘OFF’.
(3) Input SECAM CVBS 20 IRE full field signal to AV1.
(4) Adjust Cut off registers:
(4) Adjust Cut off registers:
SECAM_OFFSET_RC (R Cut off)
SECAM_OFFSET_BC (B Cut off)
SECAM_OFFSET_BC (B Cut off)
(5) The cut off registers stated in item no.4 is listed in
‘Service Menu’, accessible from TT menu
(refer 2-3).
(refer 2-3).
(6) To adjust for 20”, perform step 1~3
, then press
“TT94” (in TT MODE) and continue step 4~5.
KLV-B15G10/B20G10
Range
X
0.281/0.279
1.0
y
0.285/0.283
1.0
Y
14.46/11.47
Low light (Cut off) Adjustment Value
KLV-B15G10/B20G10
Range
X
0.272/0.281
0.5
y
0.276/0.282
0.5
Y
273.6/273.7
Highlight Adjustment Value
KLV-B15G10/B20G10
Range
X
0.261/0.273
1.0
y
0.269/0.276
1.0
Y
18.04/15.72
Low light (Cut off) Adjustment Value