KLV-26T400A, KLV-26T400G, KLV-32T400A - Sony TV Service Manual (repair manual). Page 17

Read Sony KLV-26T400A / KLV-26T400G / KLV-32T400A Service Manual online

– 16 –
KLV-26T400A, T400G, 32T400A
RM-GA013
4-2-5. AC Power Cord Wire Dressing (Before 
 
installing G1 Bracket with GPT PWB) for CISPR Models. 
4-2-6. Dressing of Connector Assy 10P and 14P
1) Install Ferrite core to AC power cord at specified position as shown. 
2) Attach Tape, Shield (X2) on to specified position. 
3) Next, wrap Sheet Core, E around area of Tape, Shield on AC power cord, to cover it.
4) Finally, install AC cord holder to AC power cord at specified position.
5) Attach Tape, Shield to AC power cord (X2) at specified position.
6) Attach Sheet Core, C to overlap the two Tape, Shields.
    
This is to prevent the Tape, Shields from peeling off.
Attach Tape, LCD to Connector Assy 10P and Connector Assy 14P as shown.
 
Use datum lines as an 
indication for attaching 
Tape, LCD to 
Connector Assy 14P 
 
 
Use datum lines as an indication for attaching
Tape, LCD to Connector Assy 10P 
Ferrite Core
Tape, Shield (X2)
Wrap Sheet Core, E around area of Tape, 
 Shield on AC Power Cord, to Cover it  
CISPR models only
Attach Sheet Core, C to Tape, Shields. 
Make sure it overlaps the Tape, Shields. 
CISPR models only
Attach Tape, Shield to AC Power Cord (X2)
Use edge of Inverter board's cover and AC power cord 
connector as a guideline for placement of power cord 
Portion of AC Power Cord with Sheet Core, E
When installing AC cord holder, make sure 
the Sheet Core, E area is clamped as well 
Attach Tape, LCD
(2X)
Dress Conn Assy 10P
below Frame, Spine 
Attach Tape, LCD (1X)
360 ± 5mm 
Ferrite Core
Tape, Shield (X2)
AC Cord Holder
Sheet Core, E
140± 5mm
285± 5mm
2
1
3
6
5
4
Page of 43
Display

Click on the first or last page to see other KLV-26T400A / KLV-26T400G / KLV-32T400A service manuals if exist.