RM-GA013
4-2-5. AC Power Cord Wire Dressing (Before
installing G1 Bracket with GPT PWB) for CISPR Models.
4-2-6. Dressing of Connector Assy 10P and 14P
1) Install Ferrite core to AC power cord at specified position as shown.
2) Attach Tape, Shield (X2) on to specified position.
3) Next, wrap Sheet Core, E around area of Tape, Shield on AC power cord, to cover it.
4) Finally, install AC cord holder to AC power cord at specified position.
5) Attach Tape, Shield to AC power cord (X2) at specified position.
6) Attach Sheet Core, C to overlap the two Tape, Shields.
This is to prevent the Tape, Shields from peeling off.
Attach Tape, LCD to Connector Assy 10P and Connector Assy 14P as shown.
Use datum lines as an
indication for attaching
Tape, LCD to
Connector Assy 14P
Use datum lines as an indication for attaching
Tape, LCD to Connector Assy 10P
Ferrite Core
Tape, Shield (X2)
Wrap Sheet Core, E around area of Tape,
Shield on AC Power Cord, to Cover it
CISPR models only
Attach Sheet Core, C to Tape, Shields.
Make sure it overlaps the Tape, Shields.
CISPR models only
Attach Tape, Shield to AC Power Cord (X2)
Use edge of Inverter board's cover and AC power cord
connector as a guideline for placement of power cord
Portion of AC Power Cord with Sheet Core, E
When installing AC cord holder, make sure
the Sheet Core, E area is clamped as well
Attach Tape, LCD
(2X)
Dress Conn Assy 10P
below Frame, Spine
Attach Tape, LCD (1X)
360 ± 5mm
Ferrite Core
Tape, Shield (X2)
AC Cord Holder
Sheet Core, E
140± 5mm