KLV-26T400A, KLV-26T400G, KLV-32T400A - Sony TV Service Manual (repair manual). Page 12

Read Sony KLV-26T400A / KLV-26T400G / KLV-32T400A Service Manual online

– 11 –
KLV-26T400A, T400G, 32T400A
RM-GA013
4-1-6. AC Power Cord Wire Dressing (Before installing G1 Bracket with GPT PWB)
4-1-7. Conn Assy 10P Dressing (Before installing
          G1 Bracket with GPT PWB)
1) Install AC cord holder to AC power cord at specified position
  as shown.
1) Install Ferrite core to AC power cord at specified position as shown
2) Next, install AC cord holder to AC power cord at specified position.
Dress Conn Assy 10P below Spine, Frame. 
Next, attach Tape, LCD (X2) to Conn Assy 10P as shown. 
CAUTION:
1. Ensure that AC power cord is not stressed whilst 
  inserting it into AC cord bracket.
Non-CISPR model
CISPR model
510 ± 5mm 
360± 5mm
Ferrite Core
CISPR models only
Attach Tape, Shield to AC Power Cord (X2)
400 ± 5mm 
1
1
Attach Sheet Core, C (X2) to 
AC Power Cord
Do not cover the 
screw holes 
with the Sheet Core, C
Use edge of Inverter board's cover and AC power cord connector 
as a guideline for placement of power cord
Use edge of Inverter board's cover and AC power cord 
connector as a guideline for placement of power cord
1. Attach Tape, Shield to AC 
Power Cord (X2)
Caution: 
Do not cover the 
screw holes with the 
Sheet Core, C
Caution: 
2. Attach Sheet Core, C (X2) to 
AC Power Cord. Make sure both 
Sheet Core, C overlaps the two 
Dress Conn Assy 
10P underneath 
Spine, Frame
Ensure Conn Assy 
10P passes through 
the slot on main 
bracket
Attach Tape, LCD (X2) to Conn Assy 10P
AC Cord Holder
2
AC Cord Holder
Page of 43
Display

Click on the first or last page to see other KLV-26T400A / KLV-26T400G / KLV-32T400A service manuals if exist.