– 6 –
KF-WE42S1/WE50S1/WS60S1
RM-1022
RM-1022
RM-1022
3.
Blinking Sequence of POWER/STANDBY LED
4.
Self-diagnosis screen display
•
For the failure which is hard to reproduce, or accompany occasional power off and/or picture mute, the Self-diagnosis screen
display is useful to specify the cause.
<To show the screen display>
•
Press the keys of the remote commander in rapid sequence as follows, when the set is in standby mode.
• One time blink is not used for self-diagnosis.
• Example
Diagnosis Times of LED blink
Lamp OFF :
3.0 sec
Lamp ON : 0.3 sec
Lamp cover 3 times
Fan
4 times
Lamp OFF : 0.3 sec
• Release of POWER/STANDBY LED blinking
The Self-Diagnosis function is released by unplugging the AC
cord temporarily.
DISPLAY
t Channel 5
t
Vol -
t POWER
J
Please note that this differs from
that of entering the service mode (Vol +).
- Numeral "1" means a fault was detected one time or more.
- Numeral "0" means that no fault was detected.
- Numeral "0" means that no fault was detected.
MA
LCD ENGINE
I
MENU operation keys
N
SELF DIagnosis
MAIN
LCD engine
6
: LOWB
0
9
: AUDIO
1
101: WDT
0
SELF DIagnosis
LCD engine
MAIN
1
: LAMP
0
3
: LAMP COVER 0
4
: FAN
0
5
: LAMP DRIVER 0
201: WDT-ENGINE 0