KE-50XS910 (serv.man2) - Sony TV Service Manual (repair manual). Page 5

Read Sony KE-50XS910 (serv.man2) Service Manual online

 
3
   High Voltage Generating Point
The places where voltage is 100V or more except for the charged 
places described above. If the places are touched, there is a risk of 
electric shock.
1. 50 X DRIVE Assy ...........................................(–230V to 223V)
2. 50 Y DRIVE Assy ...........................................................(353V)
3. 50 SCAN (A) Assy ..........................................................(353V)
4. 50 SCAN (B) Assy ..........................................................(353V)
5. X CONNECTOR AAssy ............................
(–230V to 223V)
6. X CONNECTOR B Assy ............................
(–230V to 223V)
Fig.1 Charged Section and High Voltage Generating Point (Rear View)
: Part is the High Voltage Generating Points
   other than the Charged Section.
50 Y DRIVE Assy
50 SCAN
B Assy
50 SCAN
A Assy
X CONNECTOR
B Assy
X CONNECTOR
A Assy
50 X DRIVE Assy