Leakage Current Cold Check
With the AC plug removed from an AC power source, place a 
jumper across the two plug prongs. Turn the AC power switch on. 
Using an insulation tester (DC 500V), connect one lead to the 
jumpered AC plug and touch the other lead to each exposed metal 
part (input/output terminals, screwheads, metal overlays, control 
shafts, etc.), particularly any exposed metal part having a return 
path to the chassis. Exposed metal parts having a return path to 
the chassis should have a minimum resistor reading of 0.3M
Ω 
and a maximum resistor reading of 5M
Ω. Any resistor value 
below or above this range indicates an abnormality which 
requires corrective action. Exposed metal parts not having a 
return path to the chassis will indicate an open circuit.
Leakage Current Hot Check
Plug the AC line cord directly into an AC power source (do not 
use an isolation transformer for this check). 
Turn the AC power switch on.
U s i n g   a   " L e a k a g e   C u r r e n t   Te s t e r   ( S i m p s o n   M o d e l   2 2 9  
equivalent)", measure for current from all exposed metal parts of 
the cabinet (input/output terminals, screwheads, metal overlays, 
control shaft, etc.), particularly any exposed metal part having a 
return path to the chassis, to a known earth ground (water pipe, 
conduit, etc.).  Any current measured must not exceed 0.5mA.
A N Y   M E A S U R E M E N T S   N O T   W I T H I N   T H E   L I M I T S  
OUTLINED ABOVE ARE INDICATIVE OF A POTENTIAL 
SHOCK HAZARD AND MUST BE CORRECTED BEFORE 
RETURNING THE SET TO THE CUSTOMER.
PRODUCT SAFETY NOTICE
Many electrical and mechanical parts in PIONEER set have 
special safety related characteristics. These are often not evident 
from visual inspection nor the protection afforded by them 
necessarily can be obtained by using replacement components 
rated for higher voltage, wattage, etc. Replacement parts which 
have these special safety characteristics are identified in this 
Service Manual.
Electrical components having such features are identified by 
marking with a     on the schematics and on the parts list in this 
Service Manual.
The use of a substitute replacement component which dose not 
h a v e   t h e   s a m e   s a f e t y   c h a r a c t e r i s t i c s   a s   t h e   P I O N E E R  
recommended replacement one, shown in the parts list in this 
Service Manual, may create shock, fire or other hazards.
Product Safety is continuously under review and new instructions 
are issued from time to time. For the latest information, always 
consult the current PIONEER Service Manual. A subscription to, 
or additional copies of, PIONEER Service Manual may be 
obtained at a nominal charge from PIONEER. 
Leakage
current
tester
Reading should
not be above
0.5mA
Device
under
test
Test all
exposed metal
surfaces
Also test with
plug reversed
(Using AC adapter
plug as required)
Earth
ground
AC Leakage Test