KE-32TS2E, KE-32TS2U - Sony TV Service Manual (repair manual). Page 9

Read Sony KE-32TS2E / KE-32TS2U Service Manual online

  
 
  
 
 
 
 
-6-
(3)  Video Signal Definition and Function 
The table below summarizes the definitions and functions of input video signals before   
LVDS conversion. 
 
Item 
Signal name 
Number 
of 
signals
Input/ 
output
Signal definition and function 
Video signal 
(digital RGB) 
DATA-R
DATA-G
DATA-B


Input 
Display data signal 
R7/G7/B7 is the highest intensity bit. 
R0/G0/B0 is the lowest intensity bit. 
Data Clock 
 
DCLK 
1 Input 
Display data timing signal: Data are read 
when DCLK is low. DCLK is continuously 
input. 
Horizontal sync 
signal 
_____ 
Hsync 
1 Input 
Regulates one horizontal line of data: Begins 
control of the next screen when Hsync is 
lowered. 
Vertical sync 
signal 
_____ 
Vsync 
1 Input 
Screen starts up control timing signal: Begins 
control of the next screen when Vsync is 
lowered.                                                            
Input the same frequency in both 
odd-numbered and even-numbered fields. 
Parity signal 
PARITY 
Input 
This signal specifies the display field.     
    H: Odd-numbered field   
        L: Even-numbered field                       
Parity signal should be alternated in every 
Vsync cycle. This signal is arbitrarily 
reversed internally when there is no reversing 
signal. 
Original 
Display 
signal  
(before 
LVDS 
transmitta
nce) 
Blanking signal 
  BLANK
Input 
Display period timing signal. 
H indicates the display period and L indicates 
the non display period. 
Note: 
Set this timing properly like followings, as is 
used internally for signal processing. 
Set the blanking period so that the number 
of effective display data items in one 
horizontal period is 852. 
Set the number of blanking signals in one 
vertical period to 512, which is one half the 
number of effective scan lines. 
If the BLANK changes when the Vsync 
frequency is switched, the screen display may 
be disturbed or brightness may change. 
The screen display is restored to the normal 
state later when the BLANK length is 
constant again. 
 
 
 
Page of 79
Display