-4-
1.3.3     I/0  Interface Specification 
 (1) I/O signal 
 
No. 
Item 
Signal Name 
Number 
of 
signals
I/O
 
Form 
Content of definition 
 
Reflection 
signal 
Timing  
Signal 
RXIN0- 
RXIN0+ 
RXIN1- 
RXIN1+ 
RXIN2- 
RXIN2+ 
RXIN3- 
RXIN3+ 







Input
LVDS 
Differe
ntial 
Differential serial data signal. 
Input video and timing signals 
after differential serial 
conversion using a dedicated 
transceiver. 
The serial data signal is 
transmitted seven times faster 
than the base signal. 
Clock 
RXCLKIN- 
RXCLKIN+

Input
LVDS 
Differe
ntial 
Differential clock signal. 
Input the clock signal after 
differential conversion using a 
dedicated transceiver. 
The clock signal is transmitted 
at the same speed as the base 
signal.
 
Display 
Data 
Power down 
Signal 
PDWN 1 
Input
LVTTL
Low: LVDS receiver 
outputs are all L. 
High: Input signals are 
 active.
 
SDA 1 
I/O 
Communication 
SCL 1 
I/O 
LVTTL
(I
2
C) 
I
2
C bus serial data 
communication signal. 
Communication with the 
control MPU of this product is 
enabled.
 
CPUGO 1 
Input
LVTTL
Low power consumption mode 
of the control MPU of this 
product is released.
 
PDPGO 1 
Input
LVTTL
“High”: 
This product is started.
 
(CPUGO=“High” Effective) 
 
 
 
 
 
 
 
MPU 
Comm
unicati
on/ 
Control 
Control 
IRQ 1 
Output LVTTL
It changes into "Low" Î "High" 
when this product enters the 
undermentioned state. 
1.Vcc/Va/Vs output decrease 
2.Circuit abnormality detection 
 
Page of 79
Display