KDL-60W840B, KDL-60W850B, KDL-60W855B, KDL-60W857B, KDL-70W830B, KDL-70W840B, KDL-70W850B, KDL-70W855B, KDL-70W856B, KDL-70W857B - Sony TV Service Manual (repair manual). Page 16

Read Sony KDL-60W840B / KDL-60W850B / KDL-60W855B / KDL-60W857B / KDL-70W830B / KDL-70W840B / KDL-70W850B / KDL-70W855B / KDL-70W856B / KDL-70W857B Service Manual online

Chassis: RB2G, HE-H
Chassis: RB2G, HE-H 
16
RB2G
CHASSIS
W850B
3-1-4. NO POWER – AYU2/AYU2L failure
AYU2/L Fail Suspected
eMMC / 
RawNAND erase
Product SW rewrite
No
Recover?
Product SW
writing issue
Yes
Check error message
Find Some
Error message
eMMC/ RawNAND
AYU2/L LOG is 
displayed
Yes
Store SW log
Yes
No
Check
eMMC / RawNAND
using CheckSW
No
Check DDR
using CheckSW
Find Some
Error message
No
Yes
g
It is unacceptable
error? 
Erase & Replace
Yes
(1) Check  DDR & 
eMMc / RawNAND
Replace  
AYU2/L or Board
eMMC/ RawNAND
data fail
No
Store SW log,
Check SW 
behaviors.
Yes
Data fails are 
especially in 
environment area
DDR device fail
Erase 
From the error 
message, we can 
find which device 
h
f il
Erase & Replace 
eMMC/ RawNAND
Product SW write
interface OK?
Replace Board
AYU2/L or Board
No
environment area.
If this Area has 
broken, check soft 
cannot run
In this case, corrupted 
data are written to 
eMMC/ NAND flash in 
proper way.
eMMC/ RawNAND
has failure.
Move to device 
analysis phase.
If still NG after SW 
rewrite, please go to (1) 
Check MMC/RawNAND
interface
Replace Board
So, we have to check 
the logs of exception or 
errors. 
Erase eMMC/ 
RawNAND is a last
RawNAND is a last 
option. If still NG after 
erase, please replace 
eMMC/RawNAND
 
2.1-4 - No Power: AYU2 / AYU2L Failure
Page of 112
Display

Click on the first or last page to see other KDL-60W840B / KDL-60W850B / KDL-60W855B / KDL-60W857B / KDL-70W830B / KDL-70W840B / KDL-70W850B / KDL-70W855B / KDL-70W856B / KDL-70W857B service manuals if exist.