Read Sony KDL-40BX450 / KDL-40BX451 / KDL-46BX450 / KDL-46BX451 Service Manual online
KDL-40BX450/40BX451/46BX450/46BX451 32
SECTION 5 - UPDATES AND ADJUSTMENTS
Back
<<
Color Temp
<[
Neutral
]>
R Gain
<[
538
]>
G Gain
<[
512
]>
B Gain
<[
452
]>
R Offset
<[
512
]>
G Offset
<[
512
]>
B Offset
<[
512
]>
Recall Data
<[
Off
]>
Data Backup
<[
Off
]>
[</>]Set [EXIT] Exit
Factory Mode
Color Temperature
5. Press the or to select the
Color Temp type
(Cool, Neutral, Warm1, or Warm2).
6. After the correct Color Temperature is selected, press the
to select the temperature type that needs to be modified.
7. After the correct temperature type is selected, press the
to increase the data value or press to decrease the data
value.
8. Complete the data value adjustments to the remaining
temperature items within the selected temperature type.
NOTE: Changes to the data value must be saved within the
temperature type selected before making changes to one of
the other temperature types.
9. To save the changes, press the to select
Data Backup,
then press
.
Back
<<
Color Temp
<[
Neutral
]>
R Gain
<[
538
]>
G Gain
<[
512
]>
B Gain
<[
452
]>
R Offset
<[
512
]>
G Offset
<[
512
]>
B Offset
<[
512
]>
Recall Data
<[
Off
]>
Data Backup
<[
Off
]>
[</>]Set [EXIT] Exit
Factory Mode
Color Temperature
10. Press to select the option: W/B and press
.
Back
<<
Color Temp
<[
Neutral
]>
R Gain
<[
538
]>
G Gain
<[
512
]>
B Gain
<[
452
]>
R Offset
<[
512
]>
G Offset
<[
512
]>
B Offset
<[
512
]>
Recall Data
<[
Off
]>
Data Backup
<[
W/B
]>
[</>]Set [EXIT] Exit
Factory Mode
Color Temperature
11. Do one of the following:
a. To make changes to one of the other temperature
types, repeat steps 5 through 10.
b. To exit
Factory mode, press
HOME
.