Read Sony KDL-40BX450 / KDL-40BX451 / KDL-46BX450 / KDL-46BX451 Service Manual online
KDL-40BX450/40BX451/46BX450/46BX451 30
SECTION 5 - UPDATES AND ADJUSTMENTS
6. Using the table below, verify the correct Panel Code for the
Panel ID.
Modle Name
Panel Code
Panel Type
Panel ID
KDL-40BX450
KDL-40BX451
KDL-40BX451
13_FHD_SLCD_40
SLCD
LTY400HM
KDL-46BX450
KDL-46BX451
KDL-46BX451
14_FHD_SLCD_46
SLCD
LTY460HM
7. Proceed to
Resetting the Panel Operation Time.
RESETTING PANEL OPERATION TIME
8. Press until
Self diagnosis history is selected.
9. On the
Self Check screen, identify the Panel Operation
Time location.
Back
<<
002
MAIN_ POWER
000
003
DC_ALERT1
000
003
AUDIO_PROT
000
004
BALANCER_ERR
000
005
TCON_ERR
000
005
PANEL_ID_NVM_ERR
000
006
BACKLIGHT_ERR
000
007
TEMP_ERR
000
00031
00046
00031
[Home] Exit
SELF CHECK
TOTAL OPERATION
TIME
PANEL OPERATION
TIME
BOOT COUNT
10. Press
7
0
.
11. Verify
Panel Operation Time has been changed to 00000.
Back
<<
002 MAIN_ POWER
000
003 DC_ALERT1
000
003 AUDIO_PROT
000
004 BALANCER_ERR
000
005 TCON_ERR
000
005 PANEL_ID_NVM_ERR
000
006 BACKLIGHT_ERR
000
007 TEMP_ERR
000
00031
00046
00000
[Home] Exit
SELF CHECK
12. To exit the
Self Check, press
HOME
.
Click on the first or last page to see other KDL-40BX450 / KDL-40BX451 / KDL-46BX450 / KDL-46BX451 service manuals if exist.