6
SAfETy chEck-OUT
lEakagE tESt
The AC leakage from any exposed metal part to earth ground and from all 
exposed metal parts to any exposed metal part having a return to chassis, must 
not exceed 0.5 mA(500 microamperes). Leakage current can be measured by 
any one of three methods.
1.  A commercial leakage tester, such as the Simpson 229 or RCA WT-540A. 
Follow the manufacturers’ instructions to use these instructions.
2.  A  battery-operated  AC  milliampmeter.  The  Data  Precision  245  digital 
multimeter is suitable for this job.
3.  Measuring the voltage drop across a resistor by means of a VOM or battery-
operated  AC  voltmeter.  The  “limit”  indication  is  0.75  V,  so  analog  meters 
must have an accurate low voltage scale.
 
The Simpson’s 250 and Sanwa SH-63TRD are examples of passive VOMs 
that are suitable. Nearly all battery-operated digital multimeters that have a 
2 VAC range are suitable (see Figure A).
HoW to find a good EartH ground
A cold-water pipe is a guaranteed earth ground; the cover-plate retaining screw 
on most AC outlet boxes is also at earth ground.
If the retaining screw is to be used as your earth ground, verify that it is at 
ground by measuring the resistance between it and a cold-water pipe with an 
ohmmeter. The reading should be zero ohms.
If a cold-water pipe is not accessible, connect a 60-to 100-watt trouble-light (not 
a neon lamp) between the hot side of the receptacle and the retaining screw. 
Try both slots, if necessary, to locate the hot side on the line; the lamp should 
light at normal brilliance if the screw is at ground potential (see Figure B).
Trouble Light
AC Outlet Box
Ohmmeter
Cold-water Pipe
Figure B. Checking for earth ground.