Read Sony KDL-32BX330 / KDL-32BX331 Service Manual online
9
KDL-32BX330/32BX331
KDL-32BX330/32BX331
SECTION 1: DIAGRAMS
1-1. CIRCUIT BOARDS LOCATION
1-2. PRINTED CIRCUIT BOARDS AND SCHEMATIC DIAGRAMS INFORMATION
All voltages are in V.
S : Measurement impossibility.
S : Measurement impossibility.
: B+line.
: B-line. (Actual measured value may be different).
: signal path. (RF)
Circled numbers are waveform references.
The components identified by shading and
!
symbol are critical for safety. Replace
only with part number specified.
The symbol
indicates a fast-blow fuse and is displayed on the component
side of the board. Replace only with fuse of the same rating as marked.
Les composants identifies per un trame et une marque
!
sont critiques pour la
securite. Ne les remplacer que par une piece portant le numero specifie.
Le symbole
indique une fusible a action rapide. Doit etre remplace par une
fusible de meme yaleur, comme maque.
All capacitors are in µF unless otherwise noted. pF : µµF 50WV or
less are not indicated except for electrolytics and tantalums.
All electrolytics are in 50V unless otherwise specified.
All resistors are in ohms. kΩ=1000Ω, MΩ=1000kΩ
Indication of resistance, which does not have one for rating
All electrolytics are in 50V unless otherwise specified.
All resistors are in ohms. kΩ=1000Ω, MΩ=1000kΩ
Indication of resistance, which does not have one for rating
electrical power, is as follows:
Pitch : 5mm
Rating
electrical
power
:
1
/
4
W
1
/
4
W in resistance,
1
/
10
W and
1
/
16
W in chip resistance.
: nonflammable resistor
: fusible resistor
: internal component
: panel designation and adjustment for repair
: earth ground
: earth-chassis
: earth-chassis
All variable and adjustable resistors have characteristic curve B,
unless otherwise noted.
Readings are taken with a color-bar signal input.
Readings are taken with a 10MΩ digital multimeter.
Voltages are DC with respect to ground unless otherwise noted.
Voltage variations may be noted due to normal production
Readings are taken with a color-bar signal input.
Readings are taken with a 10MΩ digital multimeter.
Voltages are DC with respect to ground unless otherwise noted.
Voltage variations may be noted due to normal production
tolerances.
Power Supply Board
A Board