Read Sony KDF-46E3000 / KDF-50E3000 Service Manual online
KDF-46E3000/50E3000
KDF-46E3000/50E3000
9
RELEASING THE POWER/STANDBY LED FLASH
Unplug the power cord from the outlet to temporarily stop the POWER/STANDBY lamp from fl ashing.
Self-Diagnostic Screen Display
For failures that are diffi cult to reproduce, or accompany occasional power off and/or picture mute, the Self-Diagnostic screen display is useful to
specify the cause.
For failures that are diffi cult to reproduce, or accompany occasional power off and/or picture mute, the Self-Diagnostic screen display is useful to
specify the cause.
VIEWING THE SELF-DIAGNOSTIC SCREEN
1. TV must be in standby mode. (Power off).
2. Press the following buttons on the Remote Commander within a second of each other:
DISPLAY
Channel
5
Volume -
POWER
NOTE: This differs from the method of accessing service mode which is Volume +
Sample Self-Diagnostic Screen Display
SELF CHECK
2 :
OVP
0
1 :
LAMP_ERR
0
0
3 :
LowB-ERROR
0
5 :
6 :
HV DETECT
LAMP_COVER
1
7 :
TEMP-ERROR
8 :
AUDIO-ERROR
0
9 :
FAN-ERROR
0
0
Name: KDF-37H1000
Serial: XXXXXXXXXX
"1" is displayed when an error is detected one or more times
"0" is displayed when no error has been detected
"0" is displayed when no error has been detected
NOTE: To refresh the Self Check menu when all the items are not displayed, press JUMP on the Remote Commander.
3. Proceed to Viewing the Self-Diagnostic Errors.
CLEARING THE SELF-DIAGNOSTIC SCREEN
The self-diagnostic results displayed on the screen are not cleared automatically, therefore you should always check the self-diagnostic screen during
repairs. When you have completed the repairs, clear the self-diagnostic screen to reset the results to “0”.
repairs. When you have completed the repairs, clear the self-diagnostic screen to reset the results to “0”.
Note: The self-diagnostic function will not be able to detect any subsequent faults after completion of the repairs unless the Self-Diagnostic
result display is cleared to reset the results to “0”.
result display is cleared to reset the results to “0”.
1. If the Self-Diagnostic screen is already displayed, proceed to step 3. If not, Power off (Set to Standby mode).
2. Press DISPLAY
Channel
5
Volume -
POWER
3. Press Channel 8
0
The status resets to 0.
4. To exit the Self-Diagnostic screen, turn the power off.
Click on the first or last page to see other KDF-46E3000 / KDF-50E3000 service manuals if exist.