Read Sony KD-32NX200U Service Manual online
- 21 -
Fig.3-5
Purity magnets
Align pips on
each magnet
each magnet
Fig.3-4
Align both Purity
magnets to the vertical
position
magnets to the vertical
position
Purity control magnets
Fig.3-6
5 Wedges
required
required
a
b
c
d
Purity control corrects
this area
this area
Deflection yoke positioning
corrects these areas
corrects these areas
Disk magnets or
rotatable disk
magnets correct
these areas (a-d)
rotatable disk
magnets correct
these areas (a-d)
Disk Magnets
GREEN
BLUE
RED
(1) Screen centre convergence [Static convergence]
1.
Input a dot pattern signal from the pattern generator.
2.
Normalize the picture setting.
3.
[Moving vertically], adjust the V.STAT magnet so that the
vertical red, green and blue dots coincide at the centre of the
screen.
vertical red, green and blue dots coincide at the centre of the
screen.
3-2. Convergence
By opening or closing the V.STAT magnet, the red green and
blue dots move in the direction indicated below.
blue dots move in the direction indicated below.
Note:
Do not adjust the H.STAT by rotating the V.STAT
magnets as this can affect the focus setting.
magnets as this can affect the focus setting.
B
G
R
B
G
R
Center dot
R
G
B
R
G
B
C1 Board
RV9001 (H STAT)
H STAT Convergence
(on mount side)
H STAT Convergence
(on mount side)
H STAT
convergence
control
V.STAT Vertical Static Magnet