RM-PJ4, VPL-ES3 - Sony Projector Service Manual (repair manual). Page 9

Read Sony RM-PJ4 / VPL-ES3 Service Manual online

1-5
VPL-ES3
1-3-6.
Power Board and Lamp Power Supply
Remove the Tunnel Outlet unit before starting the removal work.
n
In older to remove the connector that is connected to the lamp power supply block, remove the lamp
power supply first. Then, remove the connector after the lamp power supply block is raise up. Do not give
an excessive force to the harness.
7 Lamp
9 Cushion
0 Lamp power supply
1 Two stands assembly
2 Power board
8 Lamp power
     supply
     connector
5 Lamp door
4 loosen screw.
6 Loosen two screws.
3 Screw
    (+PWH  3 
x 8)
CN603
To the main board J12
From the Main board CN602
(Red and Black wires)