DPP-SV77 - Sony Other Service Manuals Service Manual (repair manual). Page 71

Read Sony DPP-SV77 Service Manual online

4-2
DPP-SV77 V1
Video 
output
Video cable
Oscilloscope
Monitor TV
DPP-SV77
Video
output
Oscilloscope
75 
Z
 terminal 
connector
DPP-SV77
4-3. LCD Contrast Check and Adjustment
1.
Tap the <LCD CONTRAST> icon on the menu.
2.
Check if all steps (5-step contrast) displayed at the center of the screen can be identified.
3.
If the identification is difficult, adjust the contrast by tapping the 
+ key or _ key in the upper area of
the screen.
When the white area cannot be identified:
Tap the 
_ key.
When the black area cannot be identified:
Tap the 
+ key.
4.
After checking that all five steps can be identified, tap a 
\ in the center of the adjustment bar.
n
When no adjustment of the five steps is required, tap a 
\ after step 2.
5.
When you hear a beep sound, the adjustment is completed.
4-4. Video Output Level Check and Adjustment
n
Connect the following equipment to this unit when performing video output level check and adjustment.
Required equipment
. Monitor TV
. Oscilloscope (a band of 30 MHz or higher)
. 75 Z terminal connector
Connection diagram
1.
Tap the <VMM OUT ADJUST> icon on the menu.
2.
Color-bar appears on the monitor.
3.
Place the probe of the oscilloscope at both ends of the mount terminal of J901 (RCA pin jack) on the
MD-43 board. Then, adjust the video output level (SYNC to 100% white) by tapping the 
+ key or _
key of the icon on the LCD so that the specifications are satisfied.
Specifications: 100% white, 1 V p-p
4.
After adjustment, tap a 
\ in the center of the adjustment bar.
5.
When you hear a beep sound, the adjustment is completed.
When a Monitor TV is connected:
When a Monitor TV is not connected:
Page of 79