Read Sony DPP-SV55 Service Manual online
5-2
DPP-SV55 V1 (UC, CE)
Current STATUS
00,01,01,05:00,05,35,20
00,00,00,33:00,00,00,00
00,01,01,05:00,05,35,20
00,00,00,33:00,00,00,00
LAST_STATUS
00,01,01,05:00,05,35,20
00,00,00,33:00,00,00,00
00,01,01,05:00,05,35,20
00,00,00,33:00,00,00,00
ERR1
00,01,01,55:25,a1,51,20
00,00,00,10:00,00,00,00
00,01,01,55:25,a1,51,20
00,00,00,10:00,00,00,00
ERR2
00,01,01,5d:26,a4,5b,20
00,00,00,33:00,00,00,00
00,01,01,5d:26,a4,5b,20
00,00,00,33:00,00,00,00
Test1
Test2
Test3
Test4
Test5
Test6/7
Exit
5-2. Error Display
In this unit, the “status of mechanical deck” can be displayed in the service mode.
Activation
1.
Turn on the power while pressing the MENU and SAVE keys.
2.
Release the MENU and SAVE keys when “Test1 ~ Test6/7 Exit” is displayed at the top of the
monitor screen.
monitor screen.
Status display of mechanical deck
1.
Move the yellow frame to “Test3” using Arrow keys (
←
and
→
) and press the ENTER key.
2.
The monitor screen is displayed as shown below.
Viewing the screen
Test3: Displays the status of a mechanical deck.
n
In this mode, the value cannot be changed.
Current STATUS: Displays the current status.
n
In this mode, the value cannot be changed.
Current STATUS: Displays the current status.
LAST STATUS:
Displays the status obtained when the power was turned off previously.
ERR1:
Displays the status obtained when an error occurs.
ERR2:
Displays the status obtained when an error occurs.
Detail of status
An example of “ERR1” is given below.
00
01
01
55
25
a1
51
20
Non-open
Number of
Number of
1
Error &
2
MD status
3
Mode
Non-open
Non-open
path
remaining
user setting
ribbon code
and print
printed
sheets
sheets
00
00
00
10
0
0
0
0
Total number of printed sheets
Non-setting
n
The error code is displayed in hexadecimal.
The error code is displayed in hexadecimal.