1-1-7. USB HOST/DEVICE COMMUNICATION
CHECK
The communication checks of the USB output terminal (USB
device) and PictBridge terminal (USB host) are performed in the
service mode.
device) and PictBridge terminal (USB host) are performed in the
service mode.
Procedure:
1.
Start the service mode. (Refer to Section 1-1-1.)
Note:
In this check, it is not required to select the item in the service
mode menu.
mode menu.
2.
Connect the PictBridge terminal with the USB output terminal
using the USB cable.
using the USB cable.
3.
Check that the following specification is satisfied.Specification:
The two characters “--” on the top right column of “USB Test”
are changed to “OK”.
The two characters “--” on the top right column of “USB Test”
are changed to “OK”.
Note:
If “NG” or “????????” is displayed, either PictBridge terminal
or USB output terminal is defective.
or USB output terminal is defective.
7.
When the Memory Stick reading and the SD card reading are
completed, pres the [ENTER] button.
completed, pres the [ENTER] button.
• When a Memory Stick and an SD card work normally so
that images can be read without error, the character OK is
displayed on the right of “Card Test” on the service mode
startup screen.
displayed on the right of “Card Test” on the service mode
startup screen.
• If a Memory Stick or an SD card is not set, or if image is not
contained in a Memory Stick and an SD card, or image cannot
be read from a Memory Stick and an SD card, background
of the screen becomes red and the character NG (No Good)
is displayed in the left bottom of a screen.
be read from a Memory Stick and an SD card, background
of the screen becomes red and the character NG (No Good)
is displayed in the left bottom of a screen.
4.
Upon completion of the check, remove the USB cable.
5.
Quit the service mode. (Refer to Section 1-1-1.)
• If either a Memory Stick or an SD card is NG (No Good),
the character NG (No Good) is displayed on the right of
“Card Test” on the service mode startup screen.
“Card Test” on the service mode startup screen.
8.
Quit the service mode. (Refer to Section 1-1-1.)