Read Sony HDR-XR150 / HDR-XR150E / HDR-XR155E (serv.man2) Service Manual online
HDR-XR150/XR150E/XR155E_L2
1-1
1. SERVICE NOTE
– ENGLISH –
1-3-3. Self-diagnosis Code Table
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
C
0
4
0
0
Non-standard battery is used.
Use the InfoLITHIUM battery.
C
0
6
0
0
The battery pack temperature is high.
Change the battery pack or place it in a cool place.
C
1
3
0
1
Memory card is unformatted.
Memory card is broken.
Memory card is broken.
Format the Memory card.
Insert a new Memory card.
Insert a new Memory card.
C
1
3
0
2
Disc access error
Remove the power source. Reconnect it again and operate
your camcorder again.
your camcorder again.
E
2
0
0
0
Flash memory data are rewritten.
Make flash memory data correct value. (Note)
E
6
1
0
0
Difficult to adjust focus
(Cannot initialize focus)
(Cannot initialize focus)
In case zooming is performed by the touch panel operation,
inspect the focus reset sensor (pin
inspect the focus reset sensor (pin
1 to 4, qk
of CN1003
on the VC-590 board).
In case zooming is not performed, inspect the focus motor
drive circuit (IC5306 on the VC-590 board).
In case zooming is not performed, inspect the focus motor
drive circuit (IC5306 on the VC-590 board).
E
6
1
1
0
Zoom operations fault
(Cannot initialize zoom lens.)
(Cannot initialize zoom lens.)
Inspect the lens block zoom MR sensor (pin
qf, wa to wf
of
CN1003 on the VC-590 board) when zooming is performed
when the zoom lever is operated, or the zoom motor drive
circuit (IC5306 on the VC-590 board) when zooming is not
performed.
when the zoom lever is operated, or the zoom motor drive
circuit (IC5306 on the VC-590 board) when zooming is not
performed.
E
6
1
1
1
The abnormalities in initialization of
the focus lens and the abnormalities
in initialization of the zoom lens oc-
curred simultaneously.
the focus lens and the abnormalities
in initialization of the zoom lens oc-
curred simultaneously.
Check both
E
: 61: 00 and E: 61: 10 of the self-diagnosis
code.
E
6
2
0
0
Handshake correction function does
not work well. (With PITCH angular
velocity sensor output stopped.)
not work well. (With PITCH angular
velocity sensor output stopped.)
Inspect PITCH angular velocity sensors (SE6602 on the MS-
431 board) peripheral circuits.
431 board) peripheral circuits.
E
6
2
0
1
Handshake correction function does
not work well. (With YAW angular
velocity sensor output stopped.)
not work well. (With YAW angular
velocity sensor output stopped.)
Inspect YAW angular velocity sensors (SE6603 on the MS-
431 board) peripheral circuits.
431 board) peripheral circuits.
E
9
2
0
1
Battery current value goes over the
max discharge current
max discharge current
Check the remaining battery power because this symptom
maybe depended on the remaining battery level, and confirm
whether or not the symptom is occurred after replacing the
battery.
If the symptom is still occurred, overhaul inspection is
needed.
Connect MS-431 board to VC-590 board via FP-1185 (VC-
MS) flexible board and connect DC/BATT harness to VC-
590 board (this is the minimum connection to periphery).
in the above state, check each output of DC/DC converter
(IC4701).
maybe depended on the remaining battery level, and confirm
whether or not the symptom is occurred after replacing the
battery.
If the symptom is still occurred, overhaul inspection is
needed.
Connect MS-431 board to VC-590 board via FP-1185 (VC-
MS) flexible board and connect DC/BATT harness to VC-
590 board (this is the minimum connection to periphery).
in the above state, check each output of DC/DC converter
(IC4701).
E
9
4
0
0
Fault of writing or erasing the flash
memory
memory
Inspect the flash memory (
IC8101
on the
VC-590
board).
E
9
4
0
2
BGM data error
Inspect the flash memory (
IC8101
on the
VC-590
board). If
it is OK, check the CPU (IC7501 on the VC-590 board).
Note: Start the Adjust Manual in the Adjust Station and refer to the “Destination data write”.
1-1. POWER SUPPLY DURING REPAIRS
In this unit, about 10 seconds after power is supplied to the battery terminal using the regulated power supply (8.4 V), the power is shut off
so
so
that the unit cannot operate.
These following method is available to prevent this.
Method:
Use the genuine AC power adaptor
1-2. PRECAUTION ON REPLACING THE VC-590 BOARD
Turn on the set and establish a USB connection , save the USB serial data before replacing the board.
DESTINATION DATA
When you replace to the repairing board, the written destination data of repairing board also might be changed to original setting.
Start the Adjust Manual in the Adjust Station and execute the “DESTINATON DATA WRITE”.
Start the Adjust Manual in the Adjust Station and execute the “DESTINATON DATA WRITE”.
After the board replacement, the error of the built-in recording media may be displayed.
in this case, execute the [DESTINATION DATA WRITE] then the error will be cleared.
If it is not cleared with [DESTINATION DATA WRITE], format the built-in recording media.
in this case, execute the [DESTINATION DATA WRITE] then the error will be cleared.
If it is not cleared with [DESTINATION DATA WRITE], format the built-in recording media.
USB SERIAL SAVE
When you replace to the repairing board, get the data from the former one.
Start the Adjust Manual in the Adjust Station and perform “USB SERIAL SAVE” to get the data.
Start the Adjust Manual in the Adjust Station and perform “USB SERIAL SAVE” to get the data.
USB SERIAL No.
The set is shipped with a unique ID (USB Serial No.) written in it.
This ID has not been written in a new board for service, and therefore it must be entered after the board replacement.
Start the Adjust Manual in the Adjust Station and execute the “USB SERIAL No. INPUT”.
This ID has not been written in a new board for service, and therefore it must be entered after the board replacement.
Start the Adjust Manual in the Adjust Station and execute the “USB SERIAL No. INPUT”.
1-3. SELF-DIAGNOSIS FUNCTION
1-3-1. Self-diagnosis Function
When problems occur while the unit is operating, the self-diagnosis function starts working, and displays on the LCD screen what to do.
Details of the self-diagnosis functions are provided in the Instruction manual.
Details of the self-diagnosis functions are provided in the Instruction manual.
1-3-2. Self-diagnosis Display
When problems occur while the unit is operating, the counter of the LCD screen shows a 4-digit display consisting of an alphabet and
numbers, which blinks at 3.2 Hz. This 5-character display indicates the “repaired by:”, “block” in which the problem occurred, and “detailed
code” of the problem.
numbers, which blinks at 3.2 Hz. This 5-character display indicates the “repaired by:”, “block” in which the problem occurred, and “detailed
code” of the problem.
1 1
3 1
C
Repaired by:
Refer to “1-3-3. Self-diagnosis Code Table” .
Indicates the appropriate
step to be taken.
E.g.
31 ....Reload the tape.
32 ....Turn on power again.
step to be taken.
E.g.
31 ....Reload the tape.
32 ....Turn on power again.
Block
Detailed Code
Blinks at 3.2Hz
C : Corrected by customer
H : Corrected by dealer
E : Corrected by service
H : Corrected by dealer
E : Corrected by service
engineer
LCD screen
C : 3 1 : 1 1
The changed portions from
Ver. 1.0 are shown in blue.
Ver. 1.0 are shown in blue.
Ver. 1.1 2010.02