HDR-TD10, HDR-TD10E (serv.man2) - Sony Movie Service Manual (repair manual). Page 6

Read Sony HDR-TD10 / HDR-TD10E (serv.man2) Service Manual online

HDR-TD10/TD10E_L2
1-2
– ENGLISH –
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
E
6
1
1
0
Zoom operations fault
(Cannot initialize zoom lens.)
Inspect the lens device zoom reset signal (pin wd of CN5001 or pin wd 
of CN5005 on the LD-281 board) when zooming is performed when 
the zoom lever is operated, and the zoom motor drive circuit (IC1601 
on the VC-625 board) when zooming is not performed.
E
6
1
1
1
The abnormalities in initialization of the focus 
lens and the abnormalities in initialization of 
the zoom lens occurred simultaneously.
Check both C: 32: 60 and E: 61: 10 of the self-diagnosis code.
E
6
1
3
0
Reset position detection error on the stepper 
iris initializing
Turn the power on to open lens barrier. Disconnect the battery or power 
cord, and then connect again.
Confirm that the iris blades in lens are working.
If iris blades do not working, check the iris motor drive IC in lens drive block (CN5001 
pin rf, t; or CN5005 pin rf, t; on LD-281 board).
If iris blades work normally, confirm that they are closing completely 
and confirm following item.
・  Case of the iris blades do not close normally Replace the lens de-
vice).
・  Case of “E: 61: 30” is appeared and iris blades closed completely.
  Confirm that communication with lens device is normal.
・  Case of LCD is not displayed normally Check that connection be-
tween lens device (CM-114) and CN1010 or CN1011 on VC-625 
board by FP-1386 flexible board.
・  Case of LCD is displayed normally Replace the lens device.
E
6
2
0
0
Handshake correction function does not work 
well. (With PITCH angular velocity sensor 
output stopped.)
Inspect PITCH angular velocity sensors (SE7501 on the VC-625 
board) peripheral circuits.
E
6
2
0
1
Handshake correction function does not work 
well. (With YAW angular velocity sensor 
output stopped.)
Inspect YAW angular velocity sensors (SE7501 on the VC-625 board) 
peripheral circuits.
E
6
2
0
2
Abnormality of IC for steadyshot.
Refer to [1-5-1. E : 62 : 02 (Abnormality of IC for Steadyshot) Oc-
curred].
E
6
2
0
3
IC for steadyshot and micro controller com-
munication abnormality among.
Inspect the steadyshot circuit (IC5501 on the LD-281 board).
E
6
2
0
4
Image vibration correction during
handshake function does not work.
Inspect the image vibration angular velocity sensors (SE7701 on the 
LD-281 board) peripheral circuits.
E
6
2
1
0
Shift lens initializing failure.
Replacement of lens device. (Note 3) If an error occurs again, replace 
the LD-281 board.
E
6
2
1
1
Shift lens overheating (Pitch)
Refer to [1-5-2. E : 62 : 11 (Shift Lens Overheating (Pitch)) Occurred].
E
6
2
1
2
Shift lens overheating (Yaw)
Refer to [1-5-3. E : 62 : 12 (Shift Lens Overheating (Yaw)) Occurred].
E
6
2
2
0
Abnormality of thermistor.
Refer to [1-5-4. E : 62 : 20 (Abnormality of Thermistor) Occurred].
E
9
1
0
1
Abnormality when flash is being charged.
Checking of flash unit or replacement of flash unit (FL40000).
E
9
1
0
2
Abnormality of flash unit.
Checking of flash unit or replacement of flash unit (FL40000).
E
9
1
0
3
Abnormality of flash unit Temperature 
detection.
Checking of flash unit or replacement of flash unit (FL40000).
E
9
2
0
1
Battery current value goes over the max 
discharge current
Check the remaining battery power because this symptom maybe 
depended on the remaining battery level, and confirm whether or 
not the symptom is occurred after replacing the battery. If the symp-
tom is still occurred, overhaul inspection is needed. Connect the 
CN4002 of MM-100 board with CN1009 of  VC-625 board.
Check each output of DC/DC converter (IC4301) on CN4001 of 
MM-100 board with the AC adaptor connected DC JACK. 
(The minimum connection to periphery)
E
9
4
0
0
Fault of writing or erasing the flash memory
Inspect the flash memory (IC8101, IC8202 on the MM-100 board).
E
9
4
0
1
Internal flash memory fault
Inspect the flash memory (IC8101, IC8202 on the MM-100 board).
E
9
4
0
2
BGM data error
Check the CPU (IC1601 on the VC-625 board).
E
9
5
0
0
GPS hardware error
Turn power off and turn power on again.
E
9
6
0
0
Map area mount error
Turn power off and turn power on again.
E
9
7
0
0
Projector  hardware error
Turn power off and turn power on again.
Note 3: When the lens device was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
1-4.  METHOD OF COPING WITH SHIFT LENS ERROR
LD-281 BOARD (SIDE A)
LD-281 BOARD (SIDE B)
IC5501
C5527
C5528
C5525
C5526
C5529
C5530
C5531
C5532
R5506
Fig. 1
Measurement points on the LD-281 board
about 330 msec
Note: The length of low section will vary a little depending on the conditions.
Fig. 2
Change in output voltage of R5506 on the LD-281 board
1-4-1. E : 62 : 02 [Abnormality of IC for Steadyshot] Occurred
Order
Procedure
1
Turn the power OFF.
2
While measuring with an oscilloscope the output voltage of R5506 in the periphery of IC5501 on the LD-281 board, turn the 
power ON to check that the output voltage immediately after the power on change as shown in Fig. 2.
3
If the output voltage change as shown in Fig. 2, replace the lens device (Note). If it does not change as shown in Fig. 2, inspect 
the camera control circuit (IC1601 of VC-625 board) periphery.
Note:  When the lens device was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
*
*
*
Page of 25
Display