HDR-PJ50, HDR-PJ50E, HDR-PJ50V, HDR-PJ50VE, HDR-XR160, HDR-XR160E (serv.man2) - Sony Movie Service Manual (repair manual). Page 6

Read Sony HDR-PJ50 / HDR-PJ50E / HDR-PJ50V / HDR-PJ50VE / HDR-XR160 / HDR-XR160E (serv.man2) Service Manual online

HDR-PJ50/PJ50E/PJ50V/PJ50VE/XR160/XR160E_L2
1-2
– ENGLISH –
1-5.  METHOD OF COPING WITH SHIFT LENS ERROR
LD-279 BOARD (SIDE B)
LD-279 BOARD (SIDE A)
IC5501
R5505
R5526
R5529
R5528
R5527
Fig. 1
Measurement points on the LD-279 board
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
E
6
1
1
0
Zoom operations fault
(Cannot initialize zoom lens.)
Inspect the lens block zoom reset signal (pin wd, wf of CN4001, pin 
rk
, if of CN4005 on the LD-279 board or pin rk, if of CN1007 on 
the VC-621 board) when zooming is performed when the zoom lever 
is operated, and the zoom motor drive circuit (IC5201 on the LD-279 
board) when zooming is not performed.
E
6
1
1
1
The abnormalities in initialization of the focus 
lens and the abnormalities in initialization of 
the zoom lens occurred simultaneously.
Check both C: 32: 60 and E: 61: 10 of the self-diagnosis code.
E
6
1
3
0
Reset position detection error on the stepper 
iris initializing
Turn the power on to open lens barrier. Disconnect the battery or power 
cord, and then connect again.
Confirm that the iris blades in lens are working.
If iris blades do not working, check the iris motor drive IC in lens 
drive block (CN4001 pin rf, to t; or CN4002 pin qj, qk on LD-279 
board).
If iris blades work normally, confirm that they are closing completely 
and confirm following item.
・ Case of the iris blades do not close normally Replace the lens 
block).
・  Case of “E: 61: 30” is appeared and iris blades closed completely.
  Confirm that communication with lens block is normal.
・  Case of LCD is not displayed normally Check that connection be-
tween CN6901 on CM-114 board and CN1004 on VC-621 board 
by FP-1324 flexible board.
・  Case of LCD is displayed normally Replace the lens block.
E
6
2
0
0
Handshake correction function does not work 
well. (With PITCH angular velocity sensor 
output stopped.)
Inspect PITCH angular velocity sensors (SE7501 on the MS-454 
board) peripheral circuits.
E
6
2
0
1
Handshake correction function does not work 
well. (With YAW angular velocity sensor 
output stopped.)
Inspect YAW angular velocity sensors (SE7501 on the MS-454 board) 
peripheral circuits.
E
6
2
0
2
Abnormality of IC for steadyshot.
Refer to [1-5-1. E : 62 : 02 (Abnormality of IC for Steadyshot) Oc-
curred].
E
6
2
0
3
IC for steadyshot and micro controller com-
munication abnormality among.
Inspect the steadyshot circuit (IC5501 on the LD-279 board).
E
6
2
0
4
Image vibration correction during
handshake function does not work.
Inspect the image vibration angular velocity sensors (SE7701 on the 
LD-279 board) peripheral circuits.
E
6
2
1
0
Shift lens initializing failure.
Replacement of lens block. (Note 3) If an error occurs again, replace 
the LD-279 board.
E
6
2
1
1
Shift lens overheating (Pitch)
Refer to [1-5-2. E : 62 : 11 (Shift Lens Overheating (Pitch)) Oc-
curred].
E
6
2
1
2
Shift lens overheating (Yaw)
Refer to [1-5-3. E : 62 : 12 (Shift Lens Overheating (Yaw)) Oc-
curred].
E
6
2
2
0
Abnormality of thermistor.
Refer to [1-5-4. E : 62 : 20 (Abnormality of Thermistor) Occurred].
E
9
1
0
1
Abnormality when flash is beingcharged.
Checking of flash unit or replacement of LED Flash/Video light 
(C7210).
E
9
1
0
2
Abnormality of LED Video light.
Checking of flash unit or replacement of LED Flash/Video light 
(C7210).
E
9
1
0
3
Abnormality of LED Video light  Tempera-
ture detection.
Checking of flash unit or replacement of LED Flash/Video light 
(C7210).
E
9
2
0
1
Battery current value goes over the max 
discharge current
Check the remaining battery power because this symptom maybe 
depended on the remaining battery level, and confirm whether or 
not the symptom is occurred after replacing the battery. If the symp-
tom is still occurred, overhaul inspection is needed. Check each out-
put of DC/DC converter (IC4301 on the VC-621 board) on VC-621 
board with connected the DC JACK (CN1008). 
(The minimum connection to periphery)
E
9
4
0
0
Fault of writing or erasing the flash 
memory
Turn power off and turn power on again.
E
9
4
0
1
Internal flash memory fault
Turn power off and turn power on again.
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
E
9
4
0
2
BGM data error
Check the CPU (IC1301 on the VC-621 board).
E
9
5
0
0
GPS hardware error
PJ50V/PJ50VE:
Check whether the FFC-254 flexible flat cable is broken,and check 
whether it is inserted imperfectly.
If there is no problem the flexible board, inspect or replacement of 
the GP-037 board.
E
9
6
0
0
Map area mount error
PJ50V/PJ50VE:
Inspect or replacement of the HDD.
E
9
7
0
0
Projector  hardware error
PJ50/PJ50E/PJ50V/PJ50VE:
Turn power off and turn power on again.
Note 3: When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
*
Page of 31
Display

Click on the first or last page to see other HDR-PJ50 / HDR-PJ50E / HDR-PJ50V / HDR-PJ50VE / HDR-XR160 / HDR-XR160E (serv.man2) service manuals if exist.