HDR-MV1 - Sony Movie Service Manual (repair manual). Page 13

Read Sony HDR-MV1 Service Manual online

HDR-MV1
2-2
– ENGLISH –
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
E
6
1
1
1
The abnormalities in initialization of 
the focus lens and the abnormalities in 
initialization of the zoom lens occurred 
simultaneously.
Turn power off and turn power on again.
E
6
1
3
0
Reset position detection error on the step-
per iris initializing
Turn the power on to open lens barrier. Disconnect the battery or 
power cord, and then connect again.
Confirm that the iris blades in lens are working.
If iris blades work normally, confirm that they are closing com-
pletely and confirm following item.
・  Case of the iris blades do not close normally, replace the lens 
block).
・  Case of “E: 61: 30” is appeared and iris blades closed completely,  
confirm that communication with lens block is normal.
・  Case of LCD is not displayed normally, check that connection 
between CN903 on CM-1001 board and CN1001 on VC-1019 
board by FP-2004 flexible board.
・  Case of LCD is displayed normally, replace the lens block.
E
6
2
0
0
Handshake correction function does not 
work well. (With PITCH angular velocity 
sensor output stopped.)
Turn power off and turn power on again.
E
6
2
0
1
Handshake correction function does not 
work well. (With YAW angular velocity 
sensor output stopped.)
Turn power off and turn power on again.
E
6
2
0
2
Abnormality of IC for steadyshot.
Turn power off and turn power on again.
E
6
2
0
3
IC for steadyshot and micro controller 
communication abnormality among.
Turn power off and turn power on again.
E
6
2
0
4
Image vibration correction during 
handshake function does not work.
Turn power off and turn power on again.
E
6
2
1
0
Shift lens initializing failure.
Replacement of lens block. (Note 3) If an error occurs again, 
replace the VC-1019 board.
E
6
2
1
1
Shift lens overheating (Pitch)
Turn power off and turn power on again.
E
6
2
1
2
Shift lens overheating (Yaw)
Turn power off and turn power on again.
E
6
2
2
0
Abnormality of thermistor.
Turn power off and turn power on again.
E
6
2
0*
Abnormality of processor.
Turn power off and turn power on again.
E
9
1
1*
Abnormality when flash is being charged.
Turn power off and turn power on again.
E
9
1
2*
Abnormality of LED Video light.
Turn power off and turn power on again.
E
9
1
3*
Abnormality of LED Video light  Tem-
perature detection.
Turn power off and turn power on again.
E
9
2
0
1
Battery current value goes over the max 
discharge current
Check the remaining battery power because this symptom may-
be depended on the remaining battery level, and confirm wheth-
er or not the symptom is occurred after replacing the battery. If 
the symptom is still occurred, overhaul inspection is needed. 
E
9
4
0
0
Fault of writing or erasing the flash 
memory
Turn power off and turn power on again.
E
9
4
0
1
Internal flash memory fault
Turn power off and turn power on again.
E
9
4
0
2
BGM data error
Turn power off and turn power on again.
E
5*
0
0
GPS hardware error
Turn power off and turn power on again.
E
6*
0
0
Map area mount error
Turn power off and turn power on again.
E
7*
0
0
Projector  hardware error
Turn power off and turn power on again.
Note 3: When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
Page of 27
Display

Click on the first or last page to see other HDR-MV1 service manuals if exist.