HDR-FX7, HDR-FX7E (serv.man4) - Sony Movie Service Manual (repair manual). Page 10

Read Sony HDR-FX7 / HDR-FX7E (serv.man4) Service Manual online

6-8
HDR-FX7/FX7E_ADJ
5.
D Page table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the A, B, D, 1A, 1B Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of A, B, D, 1A, 1B Page Data”)
Address
Initial value
Remark
NTSC PAL
10 to 15
Fixed data-1 (Initialized data)
16
Fixed data-2
17 to 56
Fixed data-1 (Initialized data)
57
Fixed data-2
58 to 79
Fixed data-1 (Initialized data)
7A
Fixed data-2
7B to FF
Fixed data-1 (Initialized data)
3.
A Page table
Note 1:
Check that the data of page: 0, address: 10 is“00”.
Note 2:
Fixed data-1: Initialized data. (Refer to“1. Initializing the
A, B, D, 1A, 1B Page Data”)
Fixed data-2: Modified data. (Refer to“2. Modification
of A, B, D, 1A, 1B Page Data”)
Address
Initial value
Remark
NTSC PAL
10
00
00
Test mode
11 to 17
Fixed data-1 (Initialized data)
18
Fixed data-2
19 to 2E
Fixed data-1 (Initialized data)
2F
Fixed data-2
30
Fixed data-1 (Initialized data)
31
Fixed data-2
32 to EF
Fixed data-1 (Initialized data)
F0
F1
F2
Fixed data-2
F3
F4 to FF
Fixed data-1 (Initialized data)
6.
1A Page table
Note 1:
If reading/writing data on pages 1A, set data: 01 to page:
0, address: 10, and then select pages: A. By this data set-
ting, the pages 1A can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the A, B, D, 1A, 1B Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of A, B, D, 1A, 1B Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to FF
Fixed data-1 (Initialized data)
7.
1B Page table
Note 1:
If reading/writing data on pages 1B, set data: 01 to page:
0, address: 10, and then select pages: B. By this data set-
ting, the pages 1B can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the A, B, D, 1A, 1B Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of A, B, D, 1A, 1B Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to FF
Fixed data-1 (Initialized data)
4.
B Page table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the A, B, D, 1A, 1B Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of A, B, D, 1A, 1B Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to FF
Fixed data-1 (Initialized data)
Page of 113
Display

Click on the first or last page to see other HDR-FX7 / HDR-FX7E (serv.man4) service manuals if exist.