Read Sony DCR-TRV890E / DCR-TRV900 / DCR-TRV900E Service Manual online
5-22
H
A
GND level
(0Vdc)
(0Vdc)
Pin No.
1
3
5
7
9
11
13
15
17
19
Signal Name
LANC SIG
EVF BL –
EVF VCO
PD VG
H START
PANEL COM
TCK
TDO
SWP
GND
Pin No.
2
4
6
8
10
12
14
16
18
20
Signal Name
EVF BL +
EVF VG
GND
PD VCO
XHD/PSIG
TMS
TDI
GND
RF IN/LANC JACK IN
RF MON
1-4.
COLOR ELECTRONIC VIEWFINDER
SYSTEM ADJUSTMENT
SYSTEM ADJUSTMENT
Note 1:
The back light (fluorescent tube) is driven by a high voltage AC
power supply. Therefore, do not touch the back light holder to
avoid electrical shock.
power supply. Therefore, do not touch the back light holder to
avoid electrical shock.
Note 2:
When replacing the LCD unit, be careful to prevent damages
caused by static electricity.
caused by static electricity.
Note 3:
Set the VF BRIGHT (Menu display) to the center.
[Adjusting connector]
Most of the measuring points for adjusting the viewfinder system
are concentrated in CN2904 of the VI-151 board.
Connect the Measuring Instruments via the CPC-8 jig (J-6082-388-
A).
The following table shows the Pin No. and signal name of CN2904.
are concentrated in CN2904 of the VI-151 board.
Connect the Measuring Instruments via the CPC-8 jig (J-6082-388-
A).
The following table shows the Pin No. and signal name of CN2904.
Table 5-1-3.
1. VCO Adjustment (VF-121 board)
Set the VCO free-run frequency. If deviated, the EVF screen will be
blurred.
blurred.
Mode
VTR stop
Signal
Arbitrary
Measurement Point
Pin 5 of CN2904 (EVF VCO) on
VI-151 board
VI-151 board
Measuring Instrument
Oscilloscope (DC range)
Adjustment Page
D
Adjustment Address
75
Specified Value
A = 1.7 ± 0.2V
Adjusting method:
1)
1)
Select page: 0, address: 01, and set data: 01.
2)
Check the GND level of the oscilloscope.
3)
Select page: D, address: 75, change the data and set the VCO
output voltage (A) to the specified value.
output voltage (A) to the specified value.
4)
Press the PAUSE button of the adjustment remote commander.
5)
Select page: 0, address: 01, and set data: 00.
Fig. 5-1-16
Fig. 5-1-17
CN2904
1
19
2
20
Remove the CPC cover
Click on the first or last page to see other DCR-TRV890E / DCR-TRV900 / DCR-TRV900E service manuals if exist.