DCR-TRV75, DCR-TRV75E, DCR-TRV80, DCR-TRV80E (serv.man4) - Sony Movie Service Manual (repair manual). Page 13

Read Sony DCR-TRV75 / DCR-TRV75E / DCR-TRV80 / DCR-TRV80E (serv.man4) Service Manual online

6-10
DCR-TRV75/TRV75E/TRV80/TRV80E
1-2-1.
INITIALIZATION OF A, D PAGE DATA
Note:
The data of page: 0, address: 10 must be “00”.
1. Initializing the A, D Page Data
Note1:
If “Initializing the A, D Page Data” is performed, all data of the A
page and D page will be initialized. (It is impossible to initialize a
single page.)
Note2:
If the A, D page data has been initialized, the following adjustments
need to be performed again.
1) Modification of A, D page data
2) Touch panel adjustment
Note3:
The power supply voltage must be 6.3 ± 0.1Vdc.
Adjusting page
A
Adjusting Address
10 to FF
Adjusting page
D
Adjusting Address
10 to 6F
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
7
03
Set the following data.
05 (DCR-TRV75/TRV80 (NTSC))
85 (DCR-TRV75E/TRV80E
(PAL))
4
7
00
Set the following data.
20 (Initializing A page)
22 (Initializing D page)
28 (Initializing A and D pages)
5
7
01
Set the following data, and press
PAUSE button.
20 (Initializing A page)
22 (Initializing D page)
28 (Initializing A and D pages)
6
7
02
Check that the data changes to
“01”
7
Perform “Modification of A, D
Page Data”.
2. Modification of A, D Page Data
If the A, D page data has been initialized, change the data of the
“Fixed data-2” address shown in the following tables by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
Processing after Completing Modification of A, D Page data
Order Page Address Data
Procedure
1
2
00
29
Set the data.
2
2
01
29
Set the data, and press PAUSE
button.
Note:
If the following symptoms occur after completing of the
“Modification of A, D page data”, check that the data of the “Fixed
data-2” addresses of A and D page are same as those of the same
model of the same destination.
1) The self-diagnosis code “E:20:00” on the LCD screen is displayed.
2) The power is shut off so that unit cannot operate.
3. A Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the A, D
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, D
Page Data”).
Address
Remark
Initial value
Initial value
NTSC PAL
00 to 0F
10 to 17
18
19 to 2A
2B
2C to 2F
2F
30 to 41
42
43 to 51
52
53
54
55 to 5C
5D
5E to 8F
90
91
92
93
94 to FF
CD
20
CF
1C
CC
1D
C4
28
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Touch panel adj.
Fixed data-1
Table. 6-1-2.
Page of 70
Display

Click on the first or last page to see other DCR-TRV75 / DCR-TRV75E / DCR-TRV80 / DCR-TRV80E (serv.man4) service manuals if exist.