DCR-TRV75, DCR-TRV75E, DCR-TRV80, DCR-TRV80E (serv.man4) - Sony Movie Service Manual (repair manual). Page 12

Read Sony DCR-TRV75 / DCR-TRV75E / DCR-TRV80 / DCR-TRV80E (serv.man4) Service Manual online

6-9
DCR-TRV75/TRV75E/TRV80/TRV80E
COVER
COVER
1-2.
INITIALIZATION OF 8, A, B, C, D, E, F, 18, 1B,
1C, 1E, 1F PAGE DATA
Note:
When reading or writing the 18, 1B, 1C, 1E or 1F page data, select
page: 0, address: 10, and set data: 01, then select 8, B, C, E or F
page. The 18, 1B, 1C, 1E or 1F page can be chosen by this data
setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
[Connection of the power supply during the initialization of the data.]
1)
Connect the regulated power supply and the digital voltmeter
to the battery terminal as shown in Fig. 6-1-8.
2)
Adjust the output voltage of the regulated power supply so that
the digital voltmeter display is 6.3 ± 0.1Vdc.
3)
Turn off the power supply.
4)
Turn on the HOLD switch of the adjusting remote commander.
5)
Turn on the power supply.
6)
Perform the initialization of the data.
Note:
This is normal though the following message is indicated on
the LCD screen.
“FOR InfoLITHIUM BATTERY ONLY”
[Initialization Procedure]
1.
Initialization of A, D page data
2.
Initialization of B, 1B page data
3.
Initialization of 8, C, 18, 1C page data
4.
Initialization of E, F, 1E, 1F page data
Fig. 6-1-8.
Digital volt meter
Battery terminal
Regulated power supply
Page of 70
Display

Click on the first or last page to see other DCR-TRV75 / DCR-TRV75E / DCR-TRV80 / DCR-TRV80E (serv.man4) service manuals if exist.