DCR-TRV738E, DCR-TRV740, DCR-TRV740E, DCR-TRV840 - Sony Movie Service Manual (repair manual). Page 120

Read Sony DCR-TRV738E / DCR-TRV740 / DCR-TRV740E / DCR-TRV840 Service Manual online

5-23
DCR-TRV738E/TRV740/TRV740E/TRV840
4. Flange Back Check
Subject
Siemens star
(2.0m from the front of the lens)
(Luminance : approx. 200 lux)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Specified Value
Focused at the TELE end and WIDE
end.
Note1:
The data of page: 0, address: 10 must be “00”.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
DIGITAL ZOOM (Menu display) ................................... OFF
4)
STEADY SHOT (Menu display) ..................................... OFF
Note2:
When the auto focus is ON, the lens can be checked if it is focused
or not by observing the data on the page 1 of the adjustment remote
commander.
1) Select page: 0, address: 03, and set data: 0F.
2) Page 1 shows the state of the focus.
1 : 00 : XX
Odd: Focused
Even: Unfocused
Checking method:
1)
Place the Siemens star 2.0m from the front of the lens.
2)
To open the IRIS, decrease the luminous intensity to the
Siemens star up to a point before noise appear on the image.
3)
Shoot the Siemens star with the zoom TELE end.
4)
Turn on the auto focus.
5)
Check that the lens is focused (Note2).
6)
Select page: 6, address: 21, and set data: 10.
7)
Shoot the Siemens star with the zoom WIDE end.
8)
Observe the TV monitor and check that the lens is focused.
Processing after Completing Adjustments:
1)
Select page: 6, address: 21, and set data: 00.
2)
Select page: 0, address: 03, and set data: 00.
5. Mechanical Shutter Adjustment
Adjustment Page
F
Adjustment Address
76 to 8F
Note1:
The data of page: 0, address: 10 must be “00”.
Input method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Input the following data to page: F, addresses: 76 to 8F.
Note2:
Press the PAUSE button of the adjustment remote commander
each time to set the data.
3)
Select page: 0, address: 01, and set data: 00.
Address
76
77
78
79
7A
7B
7C
7D
7E
7F
80
81
82
83
84
85
86
87
88
89
8A
8B
8C
8D
8E
8F
Data
40
00
34
00
30
00
2A
00
28
00
40
3A
31
31
35
1E
80
80
80
80
80
80
03
80
80
80
Page of 127
Display

Click on the first or last page to see other DCR-TRV738E / DCR-TRV740 / DCR-TRV740E / DCR-TRV840 service manuals if exist.