DCR-TRV238E, DCR-TRV239E (serv.man10) - Sony Movie Service Manual (repair manual). Page 2

Read Sony DCR-TRV238E / DCR-TRV239E (serv.man10) Service Manual online

— 2 —
DCR-TRV238E/TRV239E
Page
5-19
5-23
INCORRECT
CORRECT
3.
Flange Back Adjustment
(Using Flange Back Adjustment Chart and
Subject More Than 500m Away)
3-1. Flange Back Adjustment (1)
Subject
Flange back adjustment chart
(2.0 m from the front of the protection
glass) (Luminance: 350 ± 50 lux)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
46 to 56
Note1:
This adjustment should be carried out upon completion of
“HALL adjustment”.
Note2:
Make the lens horizontal and perform this adjustment.
Note3:
The data of page: 0, address: 10 must be “00”.
Note4:
Check that the data of page: 6, address: 02 is “00”. If not, set
data: 00 to this address, and press the PAUSE button.
3-2. Flange Back Adjustment (2)
Subject
Subject more than 500m away
(Subjects with clear contrast such
as buildings, etc.)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Adjustment Page
F
Adjustment Address
46 to 56
Note1:
Make the lens horizontal and perform this adjustment.
Note2:
The data of page: 0, address: 10 must be “00”.
Note3:
Check that the data of page: 6, address: 02 is “00”. If not, set
data: 00 to this address, and press the PAUSE button.
8. Auto White Balance & LV Standard Data Input
Subject
Clear chart
(Color reproduction adjustment frame)
Measurement Point
Display data of page 1 (Note5)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
1E, 1F, 2A to 2D
Specified Value
0FF0 to 1010
Note1:
This adjustment should be carried out upon completion of
“Color reproduction adjustments”.
Note2:
After the power is turned on, this adjustment can be done
only once.
Note3:
The data of page: 0, address: 10 must be “00”.
Note4:
Check that the data of page: 6, address: 02 is “00”. If not, set
data: 00 to this address, and press the PAUSE button.
Note5:
Displayed data of page 1 of the adjustment remote
commander.
1 : XX : XX
Display data
3.
Flange Back Adjustment
(Using Flange Back Adjustment Chart and
Subject More Than 500m Away)
3-1. Flange Back Adjustment (1)
Subject
Flange back adjustment chart
(2.0 m from the front of the protection
glass) (Luminance: 350 ± 50 lux)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
46 to 56
Note1:
This adjustment should be carried out upon completion of
“HALL adjustment”.
Note2:
Make the lens horizontal and perform this adjustment.
Note3:
The data of page: 0, address: 10 must be “00”.
Note4:
Check that the data of page: 6, address: 02 is “00”. If not, to
page: 6, address: 01, set data: 00, and press the PAUSE button.
3-2. Flange Back Adjustment (2)
Subject
Subject more than 500m away
(Subjects with clear contrast such
as buildings, etc.)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Adjustment Page
F
Adjustment Address
46 to 56
Note1:
Make the lens horizontal and perform this adjustment.
Note2:
The data of page: 0, address: 10 must be “00”.
Note3:
Check that the data of page: 6, address: 02 is “00”. If not, to
page: 6, address: 01, set data: 00, and press the PAUSE button.
8. Auto White Balance & LV Standard Data Input
Subject
Clear chart
(Color reproduction adjustment frame)
Measurement Point
Display data of page 1 (Note5)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
1E, 1F, 2A to 2D
Specified Value
0FF0 to 1010
Note1:
This adjustment should be carried out upon completion of
“Color reproduction adjustments”.
Note2:
After the power is turned on, this adjustment can be done
only once.
Note3:
The data of page: 0, address: 10 must be “00”.
Note4:
Check that the data of page: 6, address: 02 is “00”. If not, to
page: 6, address: 01, set data: 00, and press the PAUSE button.
Note5:
Displayed data of page 1 of the adjustment remote
commander.
1 : XX : XX
Display data
Changed portion.
Page of 4
Display