SERVICE MANUAL
CORRECTION-2
Correct your service manual as shown below.
DCR-TRV238E/TRV239E
RMT-814
AEP Model
East European Model
DCR-TRV238E/TRV239E
UK Model
North European Model
Russian Model
DCR-TRV238E
2.
Flange Back Adjustment
(Using Minipattern Box)
Subject
Siemens star chart with ND filter
for the minipattern box (Note1)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
46 to 56
Note1:
Dark Siemens star chart.
Note2:
This adjustment should be carried out upon completion of
“HALL adjustment”.
Note3:
Make the lens horizontal and perform this adjustment.
Note4:
The data of page: 0, address: 10 must be “00”.
Note5:
Check that the data of page: 6, address: 02 is “00”. If not, set
data: 00 to this address, and press the PAUSE button.
Page
5-18
INCORRECT
CORRECT
Ver 1.2  2002. 09
Level 2
5.
ADJUSTMENTS
Correction of Adjustments
Changed portion.
2.
Flange Back Adjustment
(Using Minipattern Box)
Subject
Siemens star chart with ND filter
for the minipattern box (Note1)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
46 to 56
Note1:
Dark Siemens star chart.
Note2:
This adjustment should be carried out upon completion of
“HALL adjustment”.
Note3:
Make the lens horizontal and perform this adjustment.
Note4:
The data of page: 0, address: 10 must be “00”.
Note5:
Check that the data of page: 6, address: 02 is “00”. If not, to
page: 6, address: 01, set data: 00, and press the PAUSE button.
— 2 —
DCR-TRV238E/TRV239E
Page
5-19
5-23
INCORRECT
CORRECT
3.
Flange Back Adjustment
(Using Flange Back Adjustment Chart and
Subject More Than 500m Away)
3-1. Flange Back Adjustment (1)
Subject
Flange back adjustment chart
(2.0 m from the front of the protection
glass) (Luminance: 350 ± 50 lux)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
46 to 56
Note1:
This adjustment should be carried out upon completion of
“HALL adjustment”.
Note2:
Make the lens horizontal and perform this adjustment.
Note3:
The data of page: 0, address: 10 must be “00”.
Note4:
Check that the data of page: 6, address: 02 is “00”. If not, set
data: 00 to this address, and press the PAUSE button.
3-2. Flange Back Adjustment (2)
Subject
Subject more than 500m away
(Subjects with clear contrast such
as buildings, etc.)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Adjustment Page
F
Adjustment Address
46 to 56
Note1:
Make the lens horizontal and perform this adjustment.
Note2:
The data of page: 0, address: 10 must be “00”.
Note3:
Check that the data of page: 6, address: 02 is “00”. If not, set
data: 00 to this address, and press the PAUSE button.
8. Auto White Balance & LV Standard Data Input
Subject
Clear chart
(Color reproduction adjustment frame)
Measurement Point
Display data of page 1 (Note5)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
1E, 1F, 2A to 2D
Specified Value
0FF0 to 1010
Note1:
This adjustment should be carried out upon completion of
“Color reproduction adjustments”.
Note2:
After the power is turned on, this adjustment can be done
only once.
Note3:
The data of page: 0, address: 10 must be “00”.
Note4:
Check that the data of page: 6, address: 02 is “00”. If not, set
data: 00 to this address, and press the PAUSE button.
Note5:
Displayed data of page 1 of the adjustment remote
commander.
1 : XX : XX
Display data
3.
Flange Back Adjustment
(Using Flange Back Adjustment Chart and
Subject More Than 500m Away)
3-1. Flange Back Adjustment (1)
Subject
Flange back adjustment chart
(2.0 m from the front of the protection
glass) (Luminance: 350 ± 50 lux)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
46 to 56
Note1:
This adjustment should be carried out upon completion of
“HALL adjustment”.
Note2:
Make the lens horizontal and perform this adjustment.
Note3:
The data of page: 0, address: 10 must be “00”.
Note4:
Check that the data of page: 6, address: 02 is “00”. If not, to
page: 6, address: 01, set data: 00, and press the PAUSE button.
3-2. Flange Back Adjustment (2)
Subject
Subject more than 500m away
(Subjects with clear contrast such
as buildings, etc.)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Adjustment Page
F
Adjustment Address
46 to 56
Note1:
Make the lens horizontal and perform this adjustment.
Note2:
The data of page: 0, address: 10 must be “00”.
Note3:
Check that the data of page: 6, address: 02 is “00”. If not, to
page: 6, address: 01, set data: 00, and press the PAUSE button.
8. Auto White Balance & LV Standard Data Input
Subject
Clear chart
(Color reproduction adjustment frame)
Measurement Point
Display data of page 1 (Note5)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
1E, 1F, 2A to 2D
Specified Value
0FF0 to 1010
Note1:
This adjustment should be carried out upon completion of
“Color reproduction adjustments”.
Note2:
After the power is turned on, this adjustment can be done
only once.
Note3:
The data of page: 0, address: 10 must be “00”.
Note4:
Check that the data of page: 6, address: 02 is “00”. If not, to
page: 6, address: 01, set data: 00, and press the PAUSE button.
Note5:
Displayed data of page 1 of the adjustment remote
commander.
1 : XX : XX
Display data
Changed portion.
— 3 —
DCR-TRV238E/TRV239E
Page
5-47
5-58E
INCORRECT
CORRECT
9.
Record of Use check (2)
Using method:
1)
The record of use data is displayed at addresses: D0, D1.
Note:
The data will be erased (reset) when the CF-2500 board
(VC-276 board CN1110 (20P)) is removed.
Initializing method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: D0 to D7, set data: 00 and press
PAUSE button for each address.
3)
Select page: D, address: 01, and set data: 00.
9.
Record of Use check (2)
Using method:
1)
The record of use data is displayed at addresses: D0, D1.
Note:
The data will be erased (reset) when the CF-2500 board
(VC-276 board CN1110 (20P)) is removed.
Initializing method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: D0 to D7, set data: 00 and press
PAUSE button for each address.
3)
Select page: 0, address: 01, and set data: 00.
  
Added portion.  
Changed portion.
3.
S VIDEO OUT Chroma Level Adjustment
(VC-276 board)
Adjusting method:
Order Page Address Data
Procedure
7
C
27
Press PAUSE button.
8
3
0C
00
Set the data, and press
PAUSE button.
9
D
FE
00
Set the data, and press
PAUSE button.
10
0
01
00
Set the data.
3.
S VIDEO OUT Chroma Level Adjustment
(VC-276 board)
Adjusting method:
Order Page Address Data
Procedure
7
C
27
Press PAUSE button.
8
Check that the burst signal
level (C) is satisfied the
specified value.
9
3
0C
00
Set the data, and press
PAUSE button.
10
D
FE
00
Set the data, and press
PAUSE button.
11
0
01
00
Set the data.
DCR-TRV238E/TRV239E
— 4 —
Sony EMCS Co.
2002I1600-1
  ©2002.9
Published by DI Customer Center
9-929-937-94
Page of 4
Display

Download Sony DCR-TRV238E / DCR-TRV239E (serv.man10) Service Manual (Repair Manual)

Here you can read online and download Sony DCR-TRV238E / DCR-TRV239E (serv.man10) Service Manual in PDF. DCR-TRV238E / DCR-TRV239E (serv.man10) service manual will guide through the process and help you recover, restore, fix, disassemble and repair Sony DCR-TRV238E / DCR-TRV239E (serv.man10) Movie. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.