DCR-TRV16, DCR-TRV16E, DCR-TRV18, DCR-TRV18E (serv.man2) - Sony Movie Service Manual (repair manual). Page 122

Read Sony DCR-TRV16 / DCR-TRV16E / DCR-TRV18 / DCR-TRV18E (serv.man2) Service Manual online

5-48
DCR-TRV16/TRV16E/TRV18/TRV18E/TRV116E/TRV118E
3-4.
VIDEO SYSTEM ADJUSTMENTS
Note1:
Before perform the video system adjustments, check that the
specified value of “36 MHz Origin Oscillation Adjustment” of
“CAMERA SYSTEM ADJUSTMENT” is satisfied.
And check that the data of page: 0, address: 10 is “00”. If not, set
data: 00 to this address.
Note2:
NTSC model: DCR-TRV16/TRV18
PAL model: DCR-TRV16E/TRV18E/TRV116E/TRV118E
1. Chroma BPF fo Adjustment (VA-117 Board)
Set the center frequency of IC4101 chroma band-pass filter.
Mode
Camera
Subject
Arbitrary
Measurement Point
CH1: Chroma signal terminal of S
VIDEO jack (75
 terminated)
CH2: Y signal terminal of S VIDEO jack
(75
 terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
28
Specified Value
A = 100mVp-p or less
B = 200mVp-p or more
Note:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
Check that the burst signal (B) is
output to the chroma signal
terminal of S VIDEO jack.
3
3
0C
04
Set the data, and press PAUSE
button.
4
C
28
Change the data for minimum
amplitude of the burst signal
level (A).
(The data should be “00” to “0F”.)
5
C
28
Press PAUSE button.
6
3
0C
00
Set the data, and press PAUSE
button.
7
Check that the burst signal level
(B) satisfies the specified value.
8
0
01
00
Set the data.
2. S VIDEO OUT Y Level Adjustment (VC-280 Board)
 Mode
Camera
Subject
Arbitrary
Measurement Point
Y signal terminal of S VIDEO jack
(75
 terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
25
Specified Value
A = 1000 ± 14mV
Note:
The data of page: 0, address: 10 must be “00”.
Switch setting:
DEMO MODE (Menu setting) ................................................ OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
3
0C
02
Set the data, and press PAUSE
button.
3
C
25
Change the data and set the Y
signal level (A) to the specified
value.
4
C
25
Press PAUSE button.
5
3
0C
00
Set the data, and press PAUSE
button.
6
0
01
00
Set the data.
CH1
CH2
A
H
CH1
H
B
When the data of page: 3, address: 0C, is 04:
When the data of page: 3, address: 0C, is 00:
Fig. 5-3-5.
H
Center of luminance line
A
Fig. 5-3-6.
Page of 127
Display

Click on the first or last page to see other DCR-TRV16 / DCR-TRV16E / DCR-TRV18 / DCR-TRV18E (serv.man2) service manuals if exist.