– 7 –
DCR-TRV140/TRV140E/TRV140M
Page
CORRECT
5-24
-
 : Points changed portion.
5-30
1-4.
ELECTRONIC  VIEWFINDER  SYSTEM
ADJUSTMENTS
Note 1:
When replacing the LCD unit, be careful to prevent dam-
ages caused by static electricity.
Note 2:
Set the VF B.L. (Menu setting) to the BRT NORMAL
 [Adjusting connector]
Most of the measuring points for adjusting the viewfinder system
are concentrated at VC-273 board CN1011. Connect the measur-
ing instruments via I/F unit for LANC control (J-6082-521-A) and
CPC jig connector (J-6082-539-A). The following table lists the
test point of I/F unit for LANC control.
Pin No.
Signal Name
Pin No.
Signal Name
N.C
BL
15
EVF VCO
14
EVF VG
N.C
BL 4.75
9
PB RF (MON)
3 (N.C)
BPF MONI
6, 8, 10,
GND
N.C
TMS
7 (N.C)
REC RF (RF IN)
N.C
TDI
N.C
TDO
5
SWP
N.C
TCK
4 (N.C)
CAP FG
2 (N.C)
IR VIDEO
Note:
 Pin No. are those of CN1011 on VC-273 board.
5-2. MECHANISM  SECTION
ADJUSTMENT
Mechanism Section adjustments, checks, and replacement of
mechanism parts, refer to the separate volume “8mm Video Me-
chanical Adjustment Manual IX   M2000 Mechanism  ”.
2-1.
ADJUSTMENT REMOTE COMMANDER
Connect the adjustment remote commander to CN1011 of VC-
273 board via I/F unit for LANC control (J-6082-521-A) and CPC
jig connector (J-6082-539-A). To operate the adjustment remote
commander, connect the AC power adapter (8.4Vdc) to the DC IN
jack of I/F unit for LANC control, or connect the L series Info-
LITHIUM battery to the battery terminal of I/F unit for LANC
control.
2-2.
HOW TO    ENTER  RECORD  MODE
WITHOUT  CASSETTE
1)
Connect the adjustment remote commander.
2) Turn the HOLD switch of the adjustment remote commander
to the ON position.
3) Close the cassette compartment without the cassette.
4) Select page: 3, address: 01, and set data: 0C, and press the
PAUSE button of the adjustment remote commander.
(The mechanism enters the record mode automatically.)
Note:
 The function buttons becomes inoperable.
5) To quit the record mode, select page: 3, address: 01, set data:
00, and press the PAUSE button of the adjustment remote com-
mander. (Whenever you want to quit the record mode, be sure
to quit following this procedure.)
[
=
[
[
[
Page of 10