DCR-TR8000E, DCR-TR8100E, DCR-TRV120, DCR-TRV120E, DCR-TRV120P, DCR-TRV125E (serv.man3) - Sony Movie Service Manual (repair manual). Page 7

Read Sony DCR-TR8000E / DCR-TR8100E / DCR-TRV120 / DCR-TRV120E / DCR-TRV120P / DCR-TRV125E (serv.man3) Service Manual online

– 11 –
DCR-TRV120/TRV120E/TRV120P/TRV125E/
TR8000E/TR8100E
1-5.
LCD SYSTEM ADJUSTMENTS
(DCR-TRV120/TRV120E/TRV120P/TRV125E)
6. COM AMP Adjustment (PD-117 board)
(Service manual page 5-31)
Set the common electrode drive signal level of LCD to the specified
value.
Mode
Camera
Subject
Arbitrary
Measurement Point
Pin 4 of CN5502 (PANEL COM)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
A7
Specified Value
NTSC model
A=6.33 
±
 0.05 Vp-p
(TYPE S 61 k model)
A=6.33 
±
 0.05 Vp-p
(TYPE S 123 k model)
A=5.40 
±
 0.05 Vp-p
(TYPE C model)
PAL model
A=6.00 
±
 0.05 Vp-p
(TYPE S 61 k model)
A=6.33 
±
 0.05 Vp-p
(TYPE S 123 k model)
A=5.05 
±
 0.05 Vp-p
(TYPE C model)
Note 1:
NTSC model: DCR-TRV120/TRV120P
PAL model: DCR-TRV120E/TRV125E
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: A7, change the data and set the PANEL
COM signal level (A) to the specified value.
3)
Press the PAUSE button.
4)
Select page: 0, address: 01, and set data: 00.
Fig. 5-1-22
A
2H
SECTION  5
ADJUSTMENTS
Page of 16
Display

Click on the first or last page to see other DCR-TR8000E / DCR-TR8100E / DCR-TRV120 / DCR-TRV120E / DCR-TRV120P / DCR-TRV125E (serv.man3) service manuals if exist.