7.
Test Pattern Output
Click the [Test Pattern Output] button on the Service Mode screen,
and the “TEST PATTERN OUTPUT” screen will appear.
Using method:
1) Select the signal source of test patterns from the following
items and click it.
• EXP
• D/A CONVERTER
2) If you clicked D/A CONVERTER, select the output type.
3) Select the type of test patterns and click it, and the signals will
be output.
4) Click the [Test Signal Cancel] button to cancel the signal out-
put.
5) Click [x] (Close button) on the right side of signal source dis-
play to return to the initial screen.
Note:
Frequent output/cancel of test signals may cause the
signal colors to be disordered. In such a case, turn off
and on the power of the camcorder.