Read Sony DCR-PC2E / DCR-PC3 / DCR-PC3E Service Manual online
5-31
1-5.
LCD SYSTEM ADJUSTMENT
Note 1:
The back light (fluorescent tube) is driven by a high voltage AC
power supply. Therefore, do not touch the back light holder to
avoid electrical shock.
power supply. Therefore, do not touch the back light holder to
avoid electrical shock.
Note 2:
When replacing the LCD unit, be careful to prevent damages
caused by static electricity.
caused by static electricity.
Note 3:
Set the function settings of the touch panel as follow.
PANEL BRIGHT .............................................................. Center
PANEL COLOR (Menu setting) ....................................... Center
PANEL BRIGHT .............................................................. Center
PANEL COLOR (Menu setting) ....................................... Center
[Adjusting connector]
Most of the measuring points for adjusting the LCD system are
concentrated in CN8201 of the PD-112 board.
The following table shows the Pin No. and signal name of CN8201.
concentrated in CN8201 of the PD-112 board.
The following table shows the Pin No. and signal name of CN8201.
Table 5-1-7
1. VCO Adjustment (PD-112 board)
Set the VCO free-run frequency. If deviated, the LCD screen will
be blurred.
be blurred.
Mode
VTR stop
Signal
No signal
Measurement Point
Pin 5 of CN8201 (VCO CENT)
Measuring Instrument
Oscilloscope (DC range)
Adjustment Page
D
Adjustment Address
84
Specified Value
A = 1.8 ± 0.1V
Adjusting method:
1)
1)
Select page: 0, address: 01, and set data: 01.
2)
Check the GND level of the oscilloscope.
3)
Select page: D, address: 84, change the data and set the PCO
output voltage (A) to the specified value.
output voltage (A) to the specified value.
4)
Press the PAUSE button.
5)
Select page: 0, address: 01, and set data: 00.
H
A
GND level
(0Vdc)
(0Vdc)
Pin No.
1
2
3
4
5
Signal Name
VG
V COM
GND
PSIG
VCO CENT
Fig. 5-1-16
CN8201
5
1
PD-112 board
Click on the first or last page to see other DCR-PC2E / DCR-PC3 / DCR-PC3E service manuals if exist.