5-17
4. MR Adjustment
The MR (Magnet resistor) adjustment of the inner focus lens is
carried out automatically. In whichever case, the focus will be
deviated during auto focusing/manual focusing.
Subject
Not required
Measurement Point
Adjustment remote commander
Measuring Instrument
Adjustment Page
F
Adjustment Address
50 to 59, 62
Specified Value1
40 to C0
Specified Value2
03 to 78
Specified Value3
88 to F8
Note1:
Make the lens horizontal and perform this adjustment.
Note2:
Perform this adjustment before “Flange Back Adjustment”.
Note3:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
BD
Set the data, and press PAUSE
button.
3
6
02
Check that the data changes to
“01”.(Note4)
4
F
50
Check that the data satisfies the
specified value 1.
5
F
51
Check that the data satisfies the
specified value 1.
6
F
52
Check that the data satisfies the
specified value 2.
7
F
53
Check that the data satisfies the
specified value 3.
8
F
54
Check that the data satisfies the
specified value 2.
9
F
55
Check that the data satisfies the
specified value 3.
10
F
56
Check that the data satisfies the
specified value 2.
11
F
57
Check that the data satisfies the
specified value 3.
12
F
58
Check that the data satisfies the
specified value 2.
13
F
59
Check that the data satisfies the
specified value 3.
Note4:
The adjustment data will be automatically input to page: F, address:
50 to 59, 62.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
0
01
00
Set the data.
Page of 127