Read Sony DCR-PC100E Service Manual online
— 12 —
2-6.
HINGE ASSEMBLY
2-7.
DC-IN CONNECTOR, BATTERY TERMINAL BOARD, FJ-25 BOARD
B
C
8
2
Hinge cover (front)
3
Change the direction
of the hinge assembly
to the direction shown
by the arrow (C).
to the direction shown
by the arrow (C).
1
Release the claw (a) in the
direction of the arrow
B
first
then release the two claws (b).
claw (b)
claw (b)
claw (a)
5
Hinge cover (rear)
4
Screw
(M1.7
×
2.5),
lock ace, p2
7
Two screws
(M1.7
×
4),
lock ace, p2
6
Two spring bolts
(M1.7
×
2.5)
[REMOVING THE HINGE ASSEMBLY]
2
PT-126
harness
(13P)
(13P)
7
Hinge assembly
4
Blind plate assembly
3
Remove
the two claws
1
PT-125
harness
(4P)
(4P)
6
FP-129 flexible board
5
Peel off the adhering portion.
A
1
Screw
(M1.7
×
2.5),
lock ace, p2
3
Two screws
(M1.7
×
2.5),
lock ace, p2
qd
Two screws
(M1.7
×
2.5),
lock ace, p2
qs
Open the
S terminal cover
in the direction of
the arrow
in the direction of
the arrow
A
4
Screw
(M1.7
×
2.5),
lock ace, p2
8
Screw
(M1.7
×
2.5),
lock ace, p2
2
DC fixed plate
5
DC-IN connector
(3P)
9
Remove
the two claws
qa
Battery terminal board (3P)
q;
Terminal
fixed plate
qf
FJ-25 board
6
Screw (+K M1.7)
7
CPC lid
Perform the disassembling after steps
1
–
6
of 2-1 is complete.
Click on the first or last page to see other DCR-PC100E service manuals if exist.