DCR-PC100, DCR-PC100E (serv.man2) - Sony Movie Service Manual (repair manual). Page 127

Read Sony DCR-PC100 / DCR-PC100E (serv.man2) Service Manual online

5-24
6. Flange Back Adjustment
(Using Flange Back Adjustment Chart and Subject
 More Than 500m Away)
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
6-1.  Flange Back Adjustment (1)
Perform this adjustment after performing “HALL Adjustment” and
“MR Adjustment”.
Subject
Flange back adjustment chart
(2.0 m from the front of the lens)
(Luminance: 350 ± 50 lux)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Adjustment Page
F
Adjustment Address
13, 4A to 4F, 5A to 62
Switch setting:
POWER .................................................................. CAMERA
NIGHT SHOT .................................................................. OFF
Adjusting method:
1)
Check that at both the zoom lens TELE end and WIDE end,
the center of the chart for the flange back adjustment and center
of the exposure screen coincide.
2)
Select page: 0, address: 01, and set data: 01.
3)
Check that the data of page: F, address: 4A to 4F, 5A to 61 is
the initial value (See table below).
4)
Select page: 6, address: 02, and check that the data is “00”.
5)
Select page: 6, address: 01, set data: 13, and press the PAUSE
button of the adjustment remote commander.
Note:
Don’t touch the zoom lever. If you touch the zoom lever, the
zoom center adjustment data will be rewritten in the value which
isn’t correct.
6)
Select page: 6, address: 01, set data: 15, and press the PAUSE
button.
(The adjustment data will be automatically input to page: F,
addresses: 13, 4A to 4F, 5A to 62.)
7)
Select page: 6, address: 02, and check that the data is “01”.
Processing after Completing Adjustments:
1)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
2)
Turn off the power and turn on again.
3)
Perform “Flange Back Adjustment (2)”.
6-2.  Flange Back Adjustment (2)
Perform this adjustment after performing “Flange Back Adjustment
(1)”.
Subject
Subject more than 500m away
(Subjects with clear contrast such as
 buildings, etc.)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Adjustment Page
F
Adjustment Address
13, 4A to 4F, 5A to 62
Switch setting:
POWER .................................................................. CAMERA
NIGHT SHOT .................................................................. OFF
Adjusting method:
1)
Set the zoom lens to the TELE end and expose a subject that is
more than 500 m away (subject with clear contrast such as
building, etc.). (Nearby subjects less than 500 m away should
not be in the screen.)
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: 6, address: 02, and check that the data is “00”.
4)
Select page: 6, address: 01, set data: 13, and press the PAUSE
button of the adjustment remote commander.
Note:
Don’t touch the zoom lever. If you touch the zoom lever, the
zoom center adjustment data will be rewritten in the value which
isn’t correct.
5)
Place a ND filter on the lens so that the optimum image is
obtain.
6)
Select page: 6, address: 01, set data: 29, and press the PAUSE
button.
(The adjustment data will be automatically input to page: F,
addresses: 13, 4A to 4F, 5A to 62.)
7)
Select page: 6, address: 02, and check that the data is “01”.
Processing after Completing Adjustments:
1)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
2)
Select page: 0, address: 01, and set data: 00.
3)
Turn off the power and turn on again.
4)
Perform “Flange Back Check”.
Address
4A
4B
4C
4D
4E
4F
5A
Data
79
4E
33
4C
81
20
46
Address
5B
5C
5D
5E
5F
60
61
Data
00
19
00
1B
00
00
00
Page of 127