DCR-PC100, DCR-PC100E (serv.man2) - Sony Movie Service Manual (repair manual). Page 125

Read Sony DCR-PC100 / DCR-PC100E (serv.man2) Service Manual online

5-22
3. HALL Adjustment
For detecting the position of the lens iris and ND filter, adjust each
AMP gain and offset.
Subject
Not required
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
17, 18, 19, 1A, 1B, 1C
Specified Value
When the data of page: 6, address: 01
is “01”: 15 to 19 (Note2)
When the data of page: 6, address: 01
is “03”: 87 to 8B (Note2)
When the data of page: 6, address: 01
is “69”: 87 to 8B (Note2)
When the data of page: 6, address: 01
is “6B”: 15 to 19 (Note2)
Note1:
Displayed data of page 1 of the adjustment remote commander.
1 : 00 : XX
Display data
Note2:
The PAUSE button of the Adjustment remote commander must be
pressed.
Switch setting:
POWER .................................................................. CAMERA
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 6, address: 94, and set data: 17.
3)
Select page: 6, address: 95, and set data: 89.
4)
Select page: 6, address: 01, set data: 6D, and press the PAUSE
button of the adjustment remote commander. (The HALL
adjustment is performed and the adjustment data is stored in
page: F, address: 17 to 1C.)
5)
Select page: 6, address: 02, and check that the data is “01”.
6)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
Checking method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: F, address: 10, set data: 39, and press the PAUSE
button.
3)
Select page: 6, address: 01, set data: 01, and press the PAUSE
button.
4)
Select page: 1, and check that the display data (Note1) satisfies
the specified value.
5)
Select page: 6, address: 01, set data: 03, and press the PAUSE
button.
6)
Select page: 1, and check that the display data (Note1) satisfies
the specified value.
7)
Select page: F, address: 10, set data: 43, and press the PAUSE
button.
8)
Select page: 6, address: 01, set data: 69, and press the PAUSE
button.
9)
Select page: 1, and check that the display data (Note1) satisfies
the specified value.
10) Select page: 6, address: 01, set data: 6B, and press the PAUSE
button.
11) Select page: 1, and check that the display data (Note1) satisfies
the specified value.
Processing after Completing Adjustments:
1)
Select page: F, address: 10, set data: 00, and press the PAUSE
button.
2)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
3)
Select page: 6, address: 94, and set data: 00.
4)
Select page: 6, address: 95, and set data: 00.
5)
Select page: 0, address: 01, and set data: 00.
4. MR Adjustment
The MR (Magnet resistor) adjustment of the inner focus lens is
carried out automatically. In whichever case, the focus will be
deviated during auto focusing/manual focusing.
Subject
Not required
Measurement Point
Adjustment remote commander
Measuring Instrument
Adjustment Page
F
Adjustment Address
50 to 59, 62
Specified Value
The data of page: F, address: 50 is
“40” to “C0”
The data of page: F, address: 51 is
“40” to “C0”
Note:
Make the lens horizontal and perform this adjustment.
Switch setting:
POWER .................................................................. CAMERA
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 6, address: 01, set data: BD, and press the PAUSE
button of the adjustment remote commander. (The MR
adjustment is performed and the adjustment data is stored in
page: F, address: 50 to 59, 62.)
3)
Select page: 6, address: 02, and check that the data is “01”.
4)
Select page: F, address: 50, and check that the data satisfies the
specified value.
5)
Select page: F, address: 51, and check that the data satisfies the
specified value.
Processing after Completing Adjustments:
1)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
2)
Select page: 0, address: 01, set data: 00.
3)
Turn off the power and turn on again.
4)
Perform “Flange Back Adjustment”.
Page of 127
Display

Click on the first or last page to see other DCR-PC100 / DCR-PC100E (serv.man2) service manuals if exist.