— 6 —
SERVICE NOTE
1.
CABINET (L) ASSEMBLY REMOVAL WHEN THE CASSETTE HOLDER STOPS
HALFWAY DURING LOADING OR UNLOADING
(Do not remove cabinet (L) assembly in the state that the cassette holder stops halfway.)
Note 1:
  Unloading operation in the state that the tape is in the set causes tape damage. So do not perform the unloading operation.
Note 2:
  Do not perform the following operation in the state that the unregulated power supply is connected.
(Disconnect battery or AC adapter)
1) Remove screws securing cabinet (L) assembly referring the “SECTION 2. DISASSEMBLY”.
2) Put cabinet (L) assembly up and apply power supply to loading motor with tester leads or the like from gaps.
2.
HANDLING THE VC, MR BOARDS
Never heat the VC and MR boards with hot air. (Malfunctions may
result.)
Also remove after dehumidifying.
+
Regulated Power Supply
4.0V 
±
 0.2V
: Loading
Cabinet (L) Assembly
Loading Motor
3.
SPECIAL PRECAUTIONS ON
DISCONNECTION OF CONNECTOR
ATTACHED TO THE  FLEXIBLE
BOARD
• Apply force in the arrow (
÷) direction and disconnect.
• Do not apply force in the * direction as this will cause the solder
(of the pin) to float easily.
• When touching the pins with the solder iron, do not touch other
parts. (Deformation may occur.)
• Ensure no folding  lines are formed on the flexible board. (This
will cause the internal copper film to cut easily.)
*
*
Connector
Flexible board