SELF-DIAGNOSIS FUNCTION
When problems occur while the unit is operating, the self-diagnosis
function starts working, and displays on the viewfinder, or LCD
screen what to do. This function consists of two display; self-
diagnosis display and service mode display.
Details of the self-diagnosis functions are provided in the Instruction
manual.
function starts working, and displays on the viewfinder, or LCD
screen what to do. This function consists of two display; self-
diagnosis display and service mode display.
Details of the self-diagnosis functions are provided in the Instruction
manual.
2.
SELF-DIAGNOSIS DISPLAY
When problems occur while the unit is operating, the counter of the
viewfinder or LCD screen consists of an alphabet and 4-digit number,
which blinks at 3.2Hz. This 5-character display indicates the
“repaired by:”, “block” in which the problem occurred, and “detailed
code” of the problem.
viewfinder or LCD screen consists of an alphabet and 4-digit number,
which blinks at 3.2Hz. This 5-character display indicates the
“repaired by:”, “block” in which the problem occurred, and “detailed
code” of the problem.
3.
SERVICE MODE DISPLAY
The service mode display shows the last self-diagnosis code shown in past.
3-1.
Display Method
While pressing the “BACK LIGHT” key, set the switch from OFF to ON, and continue pressing the “BACK LIGHT” key for 5 seconds
continuously. The service mode will be displayed, and the counter will show the backup No. and the 5-chracter self-diagnosis code.
continuously. The service mode will be displayed, and the counter will show the backup No. and the 5-chracter self-diagnosis code.
3-2.
Backup No.
The backup No. in the [ ] indicates the order in which the problem occurred. (If the Number of problems which occurred is less than 6, only
the number of problems which occurred will be shown.)
[1] : Occurred first time
the number of problems which occurred will be shown.)
[1] : Occurred first time
[4] : Occurred fourth time
[2] : Occurred second time
[5] : Occurred fifth time
[3] : Occurred third time
[6] : Occurred last time
Note:
Switching of destination can’t be done.
3-3.
End of Display
Turning OFF the power supply will end the service mode display.
Note:
The self-diagnosis display data will be kept even if the lithium battery (BT2301 of DI-085 board) is removed.
1 1
3 1
C
Repaired by:
Refer to page 1-4.
Self-diagnosis Code Table.
Self-diagnosis Code Table.
Indicates the appropriate
step to be taken.
E.g.
31 ....Reload the tape.
32 ....Turn on power again.
step to be taken.
E.g.
31 ....Reload the tape.
32 ....Turn on power again.
Block
Detailed Code
Blinks at 3.2Hz
C : Corrected by customer
H : Corrected by dealer
E : Corrected by service
H : Corrected by dealer
E : Corrected by service
engineer
Viewfinder or LCD screen
C : 3 1 : 1 1
Order of previous errors
Backup No.
Self-diagnosis Codes
C : 3 1 : 1 1
[3]
Lights up
Viewfinder or LCD screen
[3] C : 3 1 : 1 1