DCR-IP45, DCR-IP45E, DCR-IP55, DCR-IP55E (serv.man2) - Sony Movie Service Manual (repair manual). Page 8

Read Sony DCR-IP45 / DCR-IP45E / DCR-IP55 / DCR-IP55E (serv.man2) Service Manual online

1-2
DCR-IP45/IP45E/IP55/IP55E
3.
DISCHARGING OF THE FLASHLIGHT POWER SUPPLY CAPACITOR
The capacitor (C4207) of the flash unit (FL-2960) is charged up to the maximum 300V potential. There is a danger of electric shock by this
high voltage when the flash unit (FL-2960) is handled by hand. The electric shock is caused by the charged voltage which is kept without
discharging when the main power of the unit is simply turned off. Therefore, the remaining voltage must be discharged as described below.
3-1.
PREPARING THE SHORT JIG
To preparing the short jig. a small clip is attached to each end of a resistor of 1k
Ω/1W (1-215-869-11). Wrap insulating tape fully around the
reads of the resistor to prevent electric shock.
3-2.
DISCHARGING THE  CAPACITOR
1
Remove the power supply (Battery or AC power adaptor).
2
Short-circuit between TP4201 of the flash unit (FL-2960) and the GND (Mechanism chassis) with the short jig about 10 seconds.
4.
COAXIAL CONNECTOR OF THE BT CABLE
When the coaxial connector of the BT cable isn’t pulled out vertically toward the board, the connector may be damaged. So, when disconnecting
the connector, be sure to take the connector of the BT cable, and pull it out vertically toward the board.
1 k
 
/1 W
Wrap insulating tape
TP4201
C4270
Short jig
1k 
/1W resistor
(1-215-869-11)
BT cable
BT-003 board
Page of 127
Display