5-8
DCR-IP45/IP45E/IP55/IP55E
1-2.
INITIALIZATION OF 4, 8, 9, A, B, C, D,
E, F, 1B, 1E, 1F PAGE DATA
Note: When reading or writing the 1B, 1E or 1F page data, select page:
0, address: 10, and set data: 01, then select B, E or F page. The 1B,
1E or 1F page can be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1-2-1.
INITIALIZATION OF A, D PAGE DATA
Note: The data of page: 0, address: 10 must be “00”.
1. Initializing the A, D Page Data
Note1: If “Initializing the A, D Page Data” is performed, all data of the A
page and D page will be initialized. (It is impossible to initialize a
single page.)
Note2: If the A, D page data has been initialized, the following adjustments
need to be performed again.
1) Modification of A, D page data
Note3: NTSC model: DCR-IP45/IP55
PAL model: DCR-IP45E/IP55E
Adjusting page
A
Adjusting Address
10 to FF
Adjusting page
D
Adjusting Address
10 to 6C
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
7
03
Set the following data.
00 (NTSC), 80 (PAL)
4
7
00
28
Set the data.
5
7
01
28
Set the data, and press PAUSE
button.
6
7
02
Check that the data changes to
“01”
7
2
00
29
Set the data.
8
2
01
29
Set the data, and press PAUSE
button.
9
Perform “Modification of A, D
Page Data”.
2. Modification of A, D Page Data
If the A, D page data has been initialized, change the data of the
“Fixed data-2” address shown in the following tables by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
Processing after Completing Modification of A, D Page data
Order Page Address Data
Procedure
1
2
00
29
Set the data.
2
2
01
29
Set the data, and press PAUSE
button.
Note: If the following symptoms occur after completing of the
“Modification of A, D page data”, check that the data of the “Fixed
data-2” addresses of A and D page are same as those of the same
model of the same destination.
1) The self-diagnosis code “E:20:00” on the LCD screen is displayed.
2) The power is shut off so that unit cannot operate.
3. A Page Table
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the A, D
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, D
Page Data”).
Address
00 to 0F
10 to 17
18
19 to 2A
2B
2C to 2E
2F
30 to 41
42
43 to C0
C1
C2 to FF
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
Initial value
Address
Remark
Initial value
00 to 0F
10
11 to 6C
00
Test mode
Fixed data-1
Table. 5-1-2.
4. D Page Table
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the A, D
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, D
Page Data”).
Table. 5-1-3.